Kev piav qhia: FOCC tsim cov hlua fiber ntau siv cov khoom siv zoo tshaj plaws thiab cov khoom sib txuas. Txhua lub rooj sibtham raug kuaj kom ntseeg tau tias tsis muaj db poob.
Kev faib tawm yam khoom
OS2 9 25Singlemode Patchcord
Share to
Hauj lwm lawm

 

 

FOCC tsim 9/125μm ib hom fiber ntau optic cable yog tsim rau kev lag luam network, chav sib tham, chaw ua liaj ua teb, huab cia network, thiab txhua qhov chaw fiber ntau jumper cables xav tau. Nws ua tau raws li RoHS raws, thiab cov fiber ntau patch qaum yog optically kuaj rau qhov poob kom ntseeg tau zoo.

 

Qhov no 9/125 OS2 ib hom fiber ntau optic cable yog qhov zoo tagnrho rau kev sib txuas 1G / 10G / 40G / 100G ethernet kev sib txuas. Nws tuaj yeem thauj cov ntaub ntawv mus txog 10km ntawm 1310nm, lossis mus txog 40km ntawm 1550nm.

 

FC ib feem ntawm lub cable yog ua los ntawm precision FC fiber optic connector. Nws ua raws li IEC, TIA / EIA, NTT thiab JIS specifications. FC connector yog nrog PC, UPC, APC versions. Ob hom tib hom thiab multimode versions tuaj nrog zirconia ceramic ferrule. Cov FC cables yog qhov rov qab xav tau qis thiab qhov muag tsis pom thaum ua kom ntseeg tau siab tshaj plaws. FC cables yog yooj yim los yog duplex yeem, siv nrog 9/125 ib hom, 50/125 multimode lossis 62.5/125 multimode fiber.


Nta:

 

image001(001).jpg

● Simplex lossis duplex lossis ntau fiber ntau sib dhos
● Riser lossis Plenum rated, LSZH thiab RoHS cables muaj
● Tsis tshua muaj kev nkag tsis tau, IEC, TIA/EIA, Telcordia raws
● kev ua tau zoo ntawm kev rov qab poob
● Kev cai fiber ntau optic cable ntev thiab lub tsho xim
● Ntau hom fiber ntau thiab wavelengths, raug 9/125 ib hom, ►50/125 multimode thiab 62.5/125 multimode
● {{0}}.9 / 1.8 / 2.0 / 3.0 / mm sab nraud txoj kab uas hla fiber ntau optic cables
● PC, UPC, thiab APC polish hom
● Kev ntim khoom zoo, tus nqi sib tw thiab xa khoom sai heev

 

Mechanical Drawing:

 

image003(001).jpg

Daim ntawv thov:

 

● Data center thiab TLC infrastructure;
● Cov ntaub ntawv ua tes hauj lwm;
● Metro daim ntawv thov;
● Kev txiav tawm ntawm cov cuab yeej nquag;
● CATV system;
● Kev txiav tawm ntawm cov cuab yeej nquag;
● FTTx (xws li FTTB, FTTC, FTTD, FTTH).


Khoom Parameter:

 

Hom Connector FC rau FC Hom Polish APC/UPC
Fiber hom 9/125μm G657A DX 2. {4}}mm Lub wavelength 1310/1550 nm
Insertion Loss Tsawg dua lossis sib npaug rau 0.3dB Rov Los Los Ntau dua lossis sib npaug li 50dB
Yam tsawg kawg nkaus Khoov Radius 10 hli Cable Jacket pvc ua
Attenuation ntawm 1310 nm 0.36 dB/km Attenuation ntawm 1550nm 0.22 dB/km
Ua haujlwm kub -40 degree ~ +85 degree Polarity A(Tx) to B(Rx)

 

Fiber Parameter:

 

Cov khoom

Chav tsev

Specification

Cladding Tsis-Circularity

%

Tsawg dua lossis sib npaug rau 2.0

Txheej Dia

μm

245±10

Cladding-Coating Concentricity yuam kev

μm

Tsawg dua los yog sib npaug rau 1.0

Core Diameter

μm

62.5±2.5

Cladding Txoj kab uas hla

μm

125±1.0

 

FOCC Rhiav:

image009.jpg

 

 

High Quality Test Assured Program

 

Insertion poob thiab rov qab los xeem
Kev tshuaj xyuas lub ntsej muag kawg
3D interferometer xeem

 

image011(001).jpg

 

 

Cim npe nrov: FC UPC rau FC APC duplex 3. yuav

Xa kev nug