Thaum xaiv ib hom fiber ntau cable rau kev teeb tsa tshiab, kev xaiv ntawm OS1 thiab OS2 los rau koj qhov kev sib txuas tshwj xeeb, ib puag ncig kev teeb tsa, kho qhov muag transceiver, thiab yav tom ntej network yuav tsum. OS1 fiber ntau yog siv rau luv luv nyob rau hauv tsev ib hom kev sib txuas, thaum OS2 fiber muab qis attenuation thiab yog nyiam rau ntev dua - deb, sab nraum zoov, thiab scalable network deployments.
Phau ntawv qhia no piav qhia txog qhov sib txawv tiag tiag ntawm OS1 thiab OS2 fiber ntau - suav nrog cov txiaj ntsig attenuation uas tau teev tseg los ntawm cov qauv thoob ntiaj teb, kev tsim kho cable, kev muaj peev xwm nyob deb, kev sib raug zoo, thiab cov txheej txheem xaiv siv tau. Yog hais tias koj xav tau ib tug ceev txheej txheem cej luam ntawmfiber ntau cable sib dhosthiab yuav ua li cas ib hom patch cords haum rau hauv cov pawg no, cov ntu hauv qab no yuav pab tau.

Teb ceev: Thaum xaiv OS1 vs OS2 Fiber
Xaiv OS1 fiber ntauthaum koj qhov project cuam tshuam nrog kev sib txuas hauv tsev nrog luv luv ib hom txuas - piv txwv li, cov khoom siv chav, chaw ua haujlwm nraub qaum, lossis kev sib txuas hauv tsev kawm ntawv - thiab thaum OS1 attenuation kev ua tau zoo txaus rau koj cov peev nyiaj txuas.
Xaiv OS2 fiber ntauthaum koj qhov project xav tau kev sib kis ntev dua, txo qis qis, sab nraum zoov lossis sab hauv tsev / sab nraum zoov, lub nraub qaum hauv tsev kawm ntawv, metro lossis xov tooj sib txuas, lossis thaum koj xav tau ntau qhov chaw kho qhov muag rau yav tom ntej nthuav dav thiab siab dua -speed optics.
Txoj cai siv tau: yog tias koj txoj kev nyob hauv ib lub tsev thiab luv luv, OS1 tuaj yeem ua haujlwm zoo. Yog tias txoj kev hla cov tsev, khiav tawm sab nraud, lossis tuaj yeem loj hlob yav tom ntej, OS2 yuav luag txhua qhov kev nqis peev zoo dua vim tias nws muab cov nyiaj sib txuas loj dua.
Dab tsi yog OS1 thiab OS2 Fiber Cables?

OS1 thiab OS2 yog pawg ua haujlwm rauib hom fiber ntau cable, tau txhais nyob rau hauv lub thoob ntiaj teb qauv cabling tus qauvISO / IEC 11801 Kev Tswj Xyuas Kev Lag Luam. Ob leeg siv 9/125 µm ib hom fiber ntau, lub ntsiab lus me me optical core nrog 125 µm cladding txoj kab uas hla. Lub hauv paus iav fiber ntau hauv ob pawg yog feem ntau tsim rauITU-T G.652specifications - feem ntau dav deployed ib hom fiber ntau tus qauv thoob ntiaj teb.
Qhov sib txawv ntawm OS1 / OS2 tsis yog hais txog cov iav fiber ntau nws tus kheej, tab sis hais txog kev ua haujlwm ntawm cabled fiber ntau - tshwj xeeb, ntau npaum li cas cov teeb liab poob (attenuation) tag nrho cable sib dhos tau tso cai los qhia txog ib mais. Qhov no yog ib qho tseem ceeb nuance: tib G.652D fiber ntau tuaj yeem tshwm sim nyob rau hauv ob qho tib si OS1-rated thiab OS2-rated cable cov khoom, nyob ntawm seb cov kev siv cable thiab cov txiaj ntsig cabled attenuation.
Tsis txhob cuam tshuam OS1 thiab OS2 nrog OM fiber ntau hom. OS1 thiab OS2 yog ib hom hom, thaumOM 3, OM 4, thiab OM5 yog multimode fiber ntau pawg tsim los rau kev siv sib txawv thiab hom transceiver. Yog tias koj tab tom sib piv cov kev xaiv multimode, saib peb cov lus qhia ntawmOM1 multimodethiabOM2 multimodepatch kab.
OS1 vs OS2 Fiber: Sib piv Table

| Fiber hom | Ib hom (9/125 µm chav kawm) | Ib hom (9/125 µm chav kawm) |
| Qhov siab tshaj plaws attenuation (raws li ISO / IEC 11801) | 1.0 dB / km ntawm 1310 nm thiab 1550 nm | 0.4 dB / km ntawm 1310 nm, 1383 nm, thiab 1550 nm |
| Kev tsim kho kab ke | Tight-buffed (hauv tsev) | Loose- raj lossis sab hauv / sab nraum zoov tsim |
| Tej daim ntawv thov | Sab hauv tsev pob txha, cov khoom siv chav | Sab nraum zoov qaum, tsev kawm ntawv, metro, telecom, data center interconnect |
| Muaj peev xwm nyob deb | Shorter (tsuas yog siab dua attenuation) | Ntev (ua haujlwm los ntawm qis attenuation) |
| Tus nqi txheeb ze | Feem ntau qis dua | Feem ntau siab dua (nws txawv ntawm kev tsim kho thiab suav fiber ntau) |
| Yav tom ntej - pov thawj | Tsim nyog rau kev ruaj khov, luv luv hauv tsev txuas | Zoo dua rau kev nthuav dav network thiab siab dua -kev hloov kho ceev |
Ib txwm paub meej tias cov ntaub ntawv cable tseeb,Specification ntawm transceiver, thiab txuas cov peev nyiaj ua ntej xaiv qhov kawg. Cov lus saum toj no muab cov ntsiab lus siv tau, tab sis koj qhov project tej yam kev mob txiav txim siab qhov kev xaiv.
OS1 vs OS2 Fiber: Attenuation and Distance
Attenuation - qhov poob ntawm optical teeb liab raws li lub teeb mus los ntawm fiber ntau cable - yog qhov ntsuas qhov sib txawv ntawm OS1 thiab OS2. Raws liISO / IEC 11801 Kev Tswj Xyuas Kev Lag Luam, OS1 cabled fiber tso cai rau qhov siab tshaj plaws ntawm 1.0 dB / km ntawm 1310 nm thiab 1550 nm, thaum OS2 tso cai rau qhov siab tshaj plaws ntawm 0.4 dB / km ntawm 1310 nm, 1383 nm, thiab 1550 nm.

Hauv cov ntsiab lus siv tau, qhov no txhais tau hais tias dhau ntawm tib lub cable ntev, qhov txuas OS2 poob qis dua cov teeb liab ntau dua li OS1 txuas. Qhov poob qis dua muab OS2 ntau chav nyob rau hauv qhov txuas pob nyiaj siv, uas txhais tau tias ua tiav qhov kev ncua deb lossis ntau dua rau cov ntsiab lus sib txuas ntawm txoj kev.
Txawm li cas los xij, tsis txhob kho qhov kev ncua deb raws li tus lej ruaj khov raws li cov kab hluav taws xob ib leeg. Hauv kev tes hauj lwm tiag tiag, qhov siab tshaj plaws ntawm kev sib txuas yog nyob ntawm ntau yam ua haujlwm ua ke: optical transceiver lub tso tawm hluav taws xob thiab txais kev nkag siab zoo, kev khiav hauj lwm wavelength, fiber ntau attenuation ib kilometer, tus naj npawb thiab zoo ntawm connectors, splice poob, thaj vaj huam sib luag poob, ib qho khoov poob hauv txoj kev, thiab engineering kev ruaj ntseg paj uas koj tsim rau hauv kev tsim. Piv txwv li, 10GBASE-LRSFP + modulekev khiav hauj lwm ntawm 1310 nm muaj peev xwm sib txawv thiab ncav cuag 10GBASE-ER module ntawm 1550 nm - txawm nyob rau tib lub cable.
Hauv cov phiaj xwm tiag tiag, txoj kev ntev feem ntau ntev dua hauv pem teb - phiaj xwm kev ncua deb. Txoj hauv kev los ntawm cov risers, cov tais, cov kav dej, thiab thaj chaw ntxiv ntxiv cov ntsuas uas yooj yim rau kev kwv yees thaum lub sijhawm npaj.
OS1 vs OS2 Fiber: Cable Construction
OS1 cable feem ntau yog tsim nrog nruj- kev tsim kho buffered, uas ua rau nws yooj yim dua los tuav hauv cov tsev, txiav tawm ntawm thaj vaj huam sib luag, thiab txoj hauv kev los ntawm cov khoom siv hauv chav. Tight- buffered cables muaj txhua tus fiber ntau coated nrog txheej tiv thaiv, muab kev yooj yim thiab kev sib txuas ncaj qha.

OS2 cable feem ntau cuam tshuam nrog xoob- raj siv, qhov twg fibers zaum hauv gel- puv lossis qhuav- cov hlab thaiv uas tiv thaiv kev ya raws, qhov kub thiab txias, thiab kev ntxhov siab. Qhov kev tsim no zoo dua rau sab nraum zoov, hauv av, huab cua, thiab thaj chaw hauv tsev kawm ntawv duct. Ntaufiber ntau optic cablessiv nyob rau hauv sab nraum zoov qaum tes hauj lwm yog xoob-tube OS2 tsim.
Hais tias, OS1 thiab OS2 yuav tsum tsis txhob to taub tsuas yog "sab hauv tsev vs sab nraum zoov" cov ntawv lo. Ib qho OS2- ntsuas cable kuj tuaj yeem tsim nrog sab hauv tsev- cov tsho ntsuas (LSZH, PVC, lossis plenum) haum rau hauv - siv hauv tsev. Cov yam tseem ceeb yog cov khoom siv lub tsho, cov nplaim hluav taws, dej- thaiv kev tsim, tensile lub zog, thiab kev ua raws li cov cai hauv zos - tsis yog lub npe OS.
OS1 vs OS2 Fiber: Applications

Qhov twg OS1 feem ntau siv
OS1 yog qhov kev xaiv ua tau zoo rau sab hauv tsev cabling uas muaj kev ncua deb thiab ib puag ncig kev ntxhov siab tsawg. Cov ntawv thov muaj xws li cov chaw ua haujlwm hauv cov pob txha txuas ntawm cov chav hauv xov tooj, cov ntaub ntawv hauv chaw nruab nrab ntawm qhov chaw luv luv, kev lag luam LAN qaum qaum cabling nyob rau hauv ib lub tsev lossis lub tsev, thiab lub tsev kawm ntawv luv luv uas tag nrho txoj hauv kev tseem nyob hauv tsev.
Qhov twg OS2 feem ntau siv
OS2 yog qhov kev xaiv tus qauv thaum poob qis, ncav cuag ntev dua, lossis muaj kev cuam tshuam sab nraum zoov. Cov ntawv thov feem ntau suav nrogsab nraum lub tsev kawm ntawv backbonethiab tsim-rau- tsim kev sib txuas, kev sib txuas hauv xov tooj thiab kev sib txuas lus sib txuas, ISP backhaul, cov chaw hauv nroog loj, cov ntaub ntawv chaw sib txuas (DCI) ntawm cov chaw, thiab txhua qhov txuas uas yuav muaj kev nthuav dav yav tom ntej.
Rau cov chaw zov me nyuam cov ntaub ntawv niaj hnub tshwj xeeb, OS2 feem ntau nyiam dua txawm tias nyob rau hauv patching vim qhov qis attenuation txhawb siab -speed optics (100G, 400G) thiab ntom patching nrog ntau connectors nyob rau hauv txoj kev. Qhov txuas luv luv nrog ntau cov ntsiab lus patching tseem tuaj yeem ua tsis tau qhov txuas pob nyiaj siv yog tias OS1 attenuation yog marginal.
OS1 vs OS2 Fiber: Standards and Specifications

Lub npe OS1 thiab OS2 yog los ntawmISO / IEC 11801 Kev Tswj Xyuas Kev Lag Luam, thoob ntiaj teb generic cabling txuj rau cov neeg siv khoom thaj chaw. Lub hauv paus ib hom fiber ntau yog feem ntau teev rauITU-T G.652, uas txhais cov geometrical, mechanical, thiab kis tau tus cwj pwm ntawm tus qauv ib hom fiber ntau. Lwm cov qauv tsim muaj xws li IEC 60793-2-50 (kev faib tawm fiber ntau kho qhov muag), TIA-568 (North American qauv cabling), thiab EN 50173 (Tebchaws Europe tus qauv cabling).
Thaum tshuaj xyuas cov ntaub ntawv cable, saib dhau ntawm "OS1" lossis "OS2" daim ntawv lo. Txheeb xyuas qhov attenuation ntawm 1310 nm thiab 1550 nm, hom teb txoj kab uas hla, khoov kev ua tau zoo (tshwj xeeb tshaj yog rau txoj kev nruj), kev khiav hauj lwm qhov kub thiab txias, qhov ntsuas hluav taws xob thiab kev faib hluav taws xob, lub zog tensile, thiab seb lub cable puas siv dej - thaiv lossis armored siv. Raufiber ntau optic connectorsthiab patch cords, kuj xyuas cov connector polish hom - UPC los yog APC - vim qhov no cuam tshuam rov qab poob thiab compatibility.
OS1 vs OS2 Fiber: Compatibility thiab Mixing

OS1 thiab OS2 fiber ntau tuaj yeem txuas lub cev yog tias lubfiber ntau optic adaptersthiab hom connector phim - LC rau LC, SC rau SC, thiab lwm yam. Txawm li cas los xij, qhov sib xyaw OS1/OS2 txuas yuav tsum raug soj ntsuam raws li qhov tsis muaj zog tshaj qhov kev ua tau zoo thiab qhov kawg kawg - mus rau - kawg poob.
Ua ntej sib xyaw OS1 thiab OS2 nyob rau hauv tib qhov txuas, xyuas tias hom connector (LC, SC, FC, ST), connector polish (UPC lossis APC), thiab fiber ntau hom (ib hom thoob plaws) zoo ib yam. Tom qab ntawd suav tag nrho qhov kev poob qis nrog rau tag nrho cov khoom sib txuas, splices, thiab thaj vaj huam sib luag hauv txoj hauv kev, thiab sib piv qhov no tiv thaiv lub transceiver cov peev nyiaj siv hluav taws xob uas tsim nyog.
Rau lub hom phiaj- cov tes hauj lwm tseem ceeb, ua kom cov kab hluav taws xob zoo ib yam (tag nrho OS2, piv txwv li) thiab sau cov ntaub ntawv txhua ntu txo cov teeb meem kev pheej hmoo thiab ua kom yooj yim rau kev hloov kho yav tom ntej.
Yuav Ua Li Cas Xaiv Ntawm OS1 thiab OS2 Fiber
Kauj Ruam 1: Ntsuas qhov ntev ntawm txoj kev
Pib nrog txoj kev cable tiag, tsis yog qhov ncaj - kab nrug ntawm qhov kawg. suav nrog txhua txoj kev los ntawm cable tais, risers, ducts, txee, thiab thaj vaj huam sib luag. Yog tias tag nrho txoj kev luv luv thiab tag nrho sab hauv tsev, OS1 yuav txaus. Yog tias txoj kev ntev, hla ntawm cov tsev, lossis yuav txuas ntxiv mus rau yav tom ntej, OS2 yog qhov zoo dua qub.
Kauj Ruam 2: Ntsuas qhov chaw teeb tsa
Yog hais tias txoj kev tawm hauv lub tsev ntawm txhua qhov chaw, kho cov kev tsim kho cable thiab lub tsho ntaus nqi raws li qhov yuav tsum tau kuaj xyuas. Rau qhov chaw nyob sab hauv tsev, paub meej tias qhov ntsuas nplaim taws ua tau raws li cov cai hauv zos (LSZH, OFNR, OFNP, thiab lwm yam). Rau qhov chaw sab nraum zoov, txheeb xyuas cov dej- thaiv, UV tiv thaiv, lub zog tensile, thiab qhov kub thiab txias. Rau hnyav industrial lossis thaj chaw ib puag ncig, xav txogFTTA cov kev daws teeb meemnrog ruggedised connectors.
Kauj Ruam 3: Sib phim cov fiber ntau nrog cov khoom siv optical transceiver
Fiber cable thiaboptical transceiver modulesyuav tsum xaiv ua ke. A 10GBASE-LR SFP+ muaj qhov sib txawv ntawm kev ncav cuag thiab lub zog siv nyiaj ntau dua li ib100GBASE-LR4 QSFP28, txawm tias ob leeg siv tib hom fiber ntau. Tsis txhob xaiv cable raws li ib tug generic "OS1 nrug" los yog "OS2 nrug" - ib txwm muab piv cov transceiver datasheet nrog cov fiber ntau txuas.
Kauj Ruam 4: Xam cov peev nyiaj txuas
Ib qho yooj yim txuas pob nyiaj muaj xws li fiber ntau attenuation (ntev × dB / km), connector poob (feem ntau 0.3–0.5 dB ib khub mated rau standard connectors), splice poob (feem ntau 0.1 dB ib fusion splice), tej thaj vaj huam sib luag los yog ntoo khaub lig- txuas poob, khoov poob margin 2 (peb ib qho kev ruaj ntseg engineering). Yog tias qhov poob tag nrho yog qis dua qhov kho qhov muag module cov peev nyiaj siv hluav taws xob, qhov txuas yuav tsum ua haujlwm tau zoo. Yog tias cov npoo nruj dhau lawm, xav txog qis dua -tsis cable, tsawg dua cov ntsiab lus sib txuas, siab dua - cov khoom sib txuas zoo, lossis lwm qhov sib txuas.
Kauj Ruam 5: Npaj rau yav tom ntej nthuav dav
Yog tias koj lub network tom qab yuav xav tau kev ncua ntev, ntxiv cov ntsiab lus nruab nrab nruab nrab, lossis kev tsiv mus rau siab dua -kev ceev optics (xws li 100G lossis 400G), OS2 muab ntau lub taub hau. Yav tom ntej - pov thawj tsis yog tsuas yog hais txog kev ceev - nws kuj txhais tau tias tawm hauv qhov muag kom txaus rau cov khoom siv hloov kho dua tshiab thiab cov ntsiab lus txuas ntxiv uas tau ntxiv rau lub sijhawm.
OS1 vs OS2 Fiber: Xaiv Scenarios
| Scenario | Qhov xav tau tseem ceeb | Pom zoo cable | Vim li cas |
|---|---|---|---|
| 300 m sab hauv tsev riser qaum hauv ib lub tsev ua haujlwm | luv luv, sab hauv tsev, tus nqi -sensitive | OS1 tej zaum yuav txaus | Txoj kev luv luv, tag nrho sab hauv tsev, thiab cov peev nyiaj txuas tau yooj yim nrog 1.0 dB / km attenuation |
| Data center patching nrog siab -speed optics thiab ntom ntom - txuas | Tsawg poob, scalability, siab connector suav | OS2 nyiam | Ntau cov ntsiab lus thaj siv nyiaj txiag; 0.4 dB / km tawm ntau dua rau 100G / 400G optics |
| 2 km tsev kawm ntawv duct txoj kev ntawm ob lub tsev | Sab nraum zoov, kev ncua deb, kev tiv thaiv ib puag ncig | OS2 nrog sab nraum zoov xoob- raj siv | Txoj kev raug rau sab nraum zoov; qis attenuation txhawb qhov kev ncua deb nrog margin |
| Kev nkag mus rau Telecom lossis metro nraub qaum network | Kev ncua deb, poob qis, cov cab kuj - qib kev ntseeg tau | OS 2 | Tsawg attenuation yog qhov tseem ceeb rau ntev -haul txuas; xoob-tube tsim muaj kev tiv thaiv ib puag ncig |
Feem ntau yuam kev thaum xaiv OS1 lossis OS2 Fiber
Xaiv tsuas yog nyob deb.
Qhov deb tseem ceeb, tab sis nws tsuas yog ib qho kev sib txawv hauv cov peev nyiaj txuas. Cov nyiaj siv hluav taws xob transceiver, cov khoom sib txuas, cov khoom sib txuas zoo, thiab cov npoo kev nyab xeeb tag nrho cuam tshuam seb qhov txuas ua haujlwm li cas. Ib qho 500 m txuas nrog rau 6 lub ntsiab lus thiab cov khoom siv qias neeg tuaj yeem ua tsis tau txawm tias ntawm OS2 cable.
Piv txwv tias OS2 tsuas yog siv rau sab nraum zoov xwb.
OS2 cable tuaj yeem tsim nrog sab hauv tsev - cov ntaub ntawv tsho. Ntau lub chaw cov ntaub ntawv niaj hnub thiab cov tsev kawm ntawv hauv tsev kawm ntawv siv OS2 fiber ntau sab hauv tsev vim tias qhov qis qis dua muab kev ua kom zoo dua qub - tshwj xeeb tshaj yog qhov txuas nrawm.
Tsis quav ntsej txog qhov txuas pob nyiaj siv.
Xaiv txoj cai kab ntawv qeb tsis tau lees paub qhov txuas txuas. Muaj ntau cov khoom sib txuas, tsis zoo splices, nruj khoov, los yog qias neeg kawg lub ntsej muag tuaj yeem ua rau lub ntsej muag kho qhov muag hauv qab qhov xav tau ntawm transceiver. Ib txwm suav thiab sau cov peev nyiaj txuas.
Tsis meej pem OS1/OS2 nrog OM fiber ntau hom.
OS1 thiab OS2 yog ib hom hom.OM 3thiabOM 4yog pawg multimode. Lawv tsis hloov pauv thiab xav tau cov transceivers sib txawv.
Piv txwv tias OS2 yeej txhawb 100G lossis 400G.
Lub fiber cable tsuas yog ib feem ntawm qhov txuas. High-kev ua haujlwm ceev yog nyob ntawm qhov kev hloov kho qhov muag, lub hom phiaj wavelength, connector zoo, fiber ntau, thiab tag nrho cov peev nyiaj txuas ua haujlwm ua ke.
Ua ntej koj xaj: OS1 / OS2 Cable Specification Checklist
Ua ntej muab qhov kev txiav txim cable, paub meej cov lus qhia hauv qab no nrog koj tus neeg muag khoom kom paub tseeb tias cov khoom sib phim koj cov kev xav tau ntawm kev teeb tsa:
- Cable qeb: OS1 lossis OS2
- Fiber suav (tus naj npawb ntawm cov cores)
- Fiber standard: G.652D los yog raws li tau teev tseg
- Cable tsim: nruj-buffed, xoob- raj, lossis sab hauv tsev / sab nraum zoov
- Jacket hom thiab qhov ntsuas hluav taws kub: LSZH, PVC, OFNR, OFNP, lossis sab nraum zoov- ntsuas
- Hom Connector yog xaj cov hlua khi: LC, SC, FC, ST
- Connector polish: UPC lossis APC
- Insertion poob thiab rov poob los ntawm cov chaw tsim khoom daim ntawv tshaj tawm
- Ntev ntev
- Kev khiav hauj lwm qhov kub thiab txias
- Tej yam tshwj xeeb yuav tsum tau: armoured, dej- thaiv, nas{1}}resistant, thiab lwm yam.
Yog tias koj xav tau kev pab qhia txog txoj cai cable, koj tuaj yeem ua tautiv tauj peb pab neeg technicalrau cov ntaub ntawv txhawb nqa thiab txuas cov kev taw qhia txog pob nyiaj siv.
FAQ: OS1 vs OS2 Fiber
Dab tsi yog qhov txawv ntawm OS1 thiab OS2 fiber ntau?
Qhov sib txawv tseem ceeb yog cabled attenuation kev ua tau zoo. OS1 tso cai rau qhov siab tshaj plaws ntawm 1.0 dB / km, thaum OS2 tso cai rau qhov siab tshaj plaws ntawm 0.4 dB / km, raws li tau hais tseg hauvISO / IEC 11801 Kev Tswj Xyuas Kev Lag Luam. Qhov kev txo qis qis no ua rau OS2 haum rau kev ncua ntev thiab xav tau kev sib txuas ntau dua.
Puas yog OS2 ib txwm zoo dua OS1?
Tsis tas li. Rau qhov txuas hauv tsev luv luv uas qhov kev siv nyiaj txuas tau yooj yim, OS1 tuaj yeem txaus thiab tus nqi ntau dua - zoo. OS2 muab kev ua tau zoo dua rau qhov kev ncua deb, ntau dua connector suav, thiab yav tom ntej nthuav dav - tab sis txhua qhov txuas yuav tsum raug ntsuas ntawm nws tus kheej cov cai.
OS2 fiber puas tuaj yeem siv sab hauv tsev?
Yog lawm. OS2 fiber ntau tuaj yeem siv sab hauv tsev yog tias lub tsho cable, qhov ntsuas hluav taws xob, thiab kev tsim kho ua raws li cov cai hauv tsev. Qhov kev xaiv OS2 txhais tau hais tias kev ua haujlwm tsis zoo, tsis yog lub tsev -kev ua raws cai - uas nyob ntawm lub tsho cable thiab kev tsim kho.
Puas yog OS1 thiab OS2 fiber ntau tuaj yeem sib xyaw hauv tib qhov txuas?
Lawv tuaj yeem txuas lub cev yog tias cov hom txuas thiab polish tau sib xws. Txawm li cas los xij, tag nrho cov kev sib txuas yuav tsum raug xam raws li qhov attenuation ntawm txhua ntu ntxiv rau tag nrho cov connector thiab splice poob. Rau cov kev sib txuas tseem ceeb, ib pawg kab ke sib xws thoob plaws hauv txoj kev yog nyiam.
Puas yog OS1 thiab OS2 siv tib qhov txuas?
Yog, ob leeg tuaj yeem siv tib yamfiber ntau optic connectorhom - LC, SC, FC, ST, thiab lwm yam. Koj yuav tsum tau xyuas kom meej tias cov connector polish hom (UPC lossis APC) zoo ib yam ntawm qhov txuas.
Puas yog OS2 tau txais kev txhawb nqa 100G lossis 400G?
Tsis yog. Cov kab hluav taws xob tsuas yog ib qho tseem ceeb xwb . 100G thiab 400G kev txhawb nqa nyob ntawm qhov kho qhov muag transceiver module, wavelength, txuas qhov deb, connector zoo, thiab tag nrho cov peev nyiaj txuas. OS2 muab qhov txo qis qis uas xav tau rau cov siab -optics ceev, tab sis qhov txuas tiav yuav tsum raug lees paub.
Cov ntaub ntawv siv thiab cov peev txheej technical
- ISO / IEC 11801-1: 2017- General cabling rau cov neeg siv khoom thaj chaw (txhais OS1 thiab OS2 pawg)
- ITU-T G.652 (2024)- Cov yam ntxwv ntawm ib qho - hom optical fiber ntau thiab cable
- IEC 60793-2-50 - Optical fibers, khoom specifications rau chav kawm B ib leeg - hom fibers
- TIA-568 - Kev Lag Luam Kev Lag Luam Kev Lag Luam Kev Lag Luam Cable Standard (North America)
- EN 50173 - Cov ntaub ntawv thev naus laus zis, generic cabling systems (European tus qauv ua raws li ISO/IEC 11801)
Kev tshuaj xyuas los ntawm: FOCC Fiber Optic Technical Team. Kho tshiab kawg: 2025.