OS2 yog singlemode fiber ntau, tsim los ntev - kis tau tus mob. OM1, OM2, OM3, OM4 thiab OM5 yog multimode fiber ntau hom, tsim rau luv luv, siab -kev sib txuas ceev hauv cov tsev, tsev kawm ntawv thiab cov chaw zov me nyuam.
Hauv kev xyaum, OS2 yog qhov kev xaiv zoo tshaj plaws rau ntev -haul singlemode txuas thiab txhua txoj hauv kev uas yuav tsum tau ntsuas ntau tshaj li ob peb puas meters, thaum OM3 thiab OM4 feem ntau nyiam luv luv - mus txog cov ntaub ntawv chaw thiab kev lag luam multimode kev sib txuas. OM5 lub hom phiaj tshwj xeeb kev siv dav dav, thiab OM1 thiab OM2 tam sim no tsuas yog siv rau kev saib xyuas qub txeeg qub teg.
Cov lus qhia no piv rau 6 hom fiber ntau los ntawm cov tub ntxhais loj, wavelength, modal bandwidth thiab kev txhawb nqa nyob deb ntawm 1G, 10G, 40G thiab 100G, tom qab ntawd taug kev los ntawm kev xaiv, sib tov thiab txheeb xyuas lawv hauv cov tes hauj lwm tiag tiag.
OS Singlemode vs OM Multimode
OS fiber ntau (Optical Singlemode) muaj qhov me me 9/125 µm core thiab nqa ib txoj kev teeb pom kev ntawm 1310 nm lossis 1550 nm. Cov tub ntxhais nqaim yuav luag tshem tawm modal dispersion, uas yog vim li cas singlemode fiber dominates telecom backbones, metro networks thiab data center interconnects.
OM fiber ntau (Optical Multimode) muaj cov tub ntxhais loj dua - 62.5/125 µm rau OM1, 50/125 µm rau OM2 txog OM5 - thiab nqa ntau txoj kev teeb pom kev ib txhij ntawm 850 nm lossis 1300 nm. Cov tub ntxhais dav dav tso cai pheej yig dua LED lossis VCSEL transceivers, uas ua rau ntau hom fiber ntau txaus nyiam rau luv luv txuas hauv lub tsev lossis cov ntaub ntawv chaw.
Ib txoj cai siv tau los ntawm cov kws ua haujlwm cabling feem ntau:
- SivOS2 singlemode patch cordsthaum nyob deb, yav tom ntej singlemode optics, los yog lub tsev - mus rau - tsev mus txog qhov teeb meem.
- Siv OM3 los yog OM4 rau feem ntau niaj hnub luv luv - ncav cuag 10G, 25G, 40G thiab 100G txuas hauv cov ntaub ntawv chaw.
- Siv OM5 tsuas yog thaum tus qauv transceiver tshwj xeeb tau txais txiaj ntsig los ntawm wideband lossis SWDM optics.
- Khaws OM1 thiab OM2 rau kev tswj hwm cov txheej txheem qub txeeg qub teg uas twb muaj lawm es tsis yog rau kev xa mus nrawm dua tshiab.
-

OS2 vs OM1, OM2, OM3, OM4, OM5 Comparison Table
Cov lus hauv qab no qhia txog cov ntsiab lus sib txawv. Qhov deb suav tias cov qauv-raws li transceivers xws li 1000BASE-SX/LX, 10GBASE-SR/LR, 40GBASE-SR4 thiab 100GBASE-SR4 raws li tau hais tseg hauv IEEE 802.3; kev ncav cuag qhov tseeb nyob ntawm qhov optics, qhov txuas tsis tau thiab cov khoom siv tau siv.
| Hom Fiber | Hom | Core / Cladding | Lub wavelength | Modal Bandwidth (MHz · km) | Jacket Xim | Zoo tshaj plaws |
|---|---|---|---|---|---|---|
| OS 2 | Singlemode | 9 / 125 µm | 1310/1550 nm | N/A | Daj | Ntev -haul, campus backbone, DCI |
| OM 1 | Multimode | 62.5 / 125 µm | 850 / 1300 nm | 200 @ 850 nm | Txiv kab ntxwv | Legacy 1G thiab hauv qab no |
| OM 2 | Multimode | 50 / 125 µm | 850 / 1300 nm | 500 @ 850 nm | Txiv kab ntxwv | Txoj cai luv luv 1G-10G |
| OM 3 | Laser - optimized MM | 50 / 125 µm | 850nm (VCSEL) | 2000 @ 850 nm | Aqua | Tus nqi -zoo 10G–40G data center |
| OM 4 | Laser - optimized MM | 50 / 125 µm | 850nm (VCSEL) | 4700 @ 850 nm | Aqua / Violet | Niaj hnub no 10G-100G luv ncav cuag |
| OM 5 | Wideband MM | 50 / 125 µm | 850–953 nm | 4700 @ 850 nm, 2470 @ 953 nm | Txiv qaub ntsuab | SWDM thiab wideband multimode |

OS2, OM3, OM4 thiab OM5 Distance by Speed
Qhov no yog lo lus nug uas engineers feem ntau xav tau teb: deb npaum li cas txhua fiber ntau yuav nqa tau Ethernet ceev? Cov lej hauv qab no ua rawsIEEE 802.3 Ethernet qauvthiab covTSI-492multimode fiber ntau pawg.
| Txuj | OM 1 | OM 2 | OM 3 | OM 4 | OM 5 | OS 2 |
|---|---|---|---|---|---|---|
| 1000BASE-SX (1G) | 275 m | 550 m | 550 m | 550 m | 550 m | - |
| 1000BASE-LX (1G) | 550 m | 550 m | 550 m | 550 m | 550 m | 5km ua |
| 10GBASE-SR (10G) | 33 m | 82 m | 300 m | 400 m | 400 m | - |
| 10GBASE-LR (10G) | - | - | - | - | - | 10km ua |
| 40GBASE-SR4 (40G) | - | - | 100 m | 150 m | 150 m | - |
| 40GBASE-LR4 (40G) | - | - | - | - | - | 10km ua |
| 100GBASE-SR4 (100G) | - | - | 70 m | 100 m | 100 m | - |
| 100GBASE-SWDM4 (100G) | - | - | 75 m | 100 m | 150 m | - |
| 100GBASE-LR4 (100G) | - | - | - | - | - | 10km ua |
Ob tug qauv sawv tawm. Ua ntej, OM4 yuav koj 30-50% ncav cuag ntau dua OM3 ntawm 10G thiab 100G, thiab lub taub hau feem ntau tsim nyog tus nqi sib txawv me me rau ib qho cable uas koj tsis tuaj yeem hloov tau yooj yim tom qab. Thib ob, OS2 yog tib qho fiber ntau hauv daim ntawv teev npe no uas ua haujlwm kilometer- nplai txuas yam tsis muaj kev rov tsim dua tshiab, uas yog vim li cas nws ua rau lub hauv paus tsev kawm ntawv thiab cov ntaub ntawv chaw sib cuam tshuam.

OS2 Fiber yog dab tsi?
OS2 yog qhov qis- dej-peak singlemode fiber ntau (ITU-T G.652.D) ua kom zoo rau qhov ntev -nruab deb thiab siab-kev ua haujlwm kis tau zoo thoob plaws 1260–1625 nm ntau yam. Vim hais tias 9 µm core txhawb nqa ib qho tseem ceeb ntawm kev nthuav tawm, modal dispersion raug tshem tawm thiab chromatic dispersion dhau los ua qhov txwv tsis pub tshaj - thiab uas tuaj yeem them nyiaj hluav taws xob los yog nrog kev sib cais - hloov pauv fiber ntau.
OS2 yog txoj cai hu rau kev sib txuas lus hauv xov tooj, kev sib txuas ntawm cov cab kuj, xov tooj cua, cov pob txha ntev hauv tsev kawm ntawv thiab cov ntaub ntawv chaw sib cuam tshuam. Yog tias koj tus qauv tsim yuav tsum hla txoj kev, qhov chaw nres tsheb, kab vaj tsev, lossis kom mus txog thoob plaws ntau - tsev kawm ntawv, OS2 yuav luag txhua qhov kev xaiv kev nyab xeeb dua. Tshiab singlemode fiber ntau kuj yog ib feem me me ntawm cov nqi zog thiab cov kav dej, yog li dhau - qhia txog nws tsis tshua mob.
OS2 tsis yog qhov kev xaiv pheej yig tshaj plaws rau kev txuas luv luv, txawm li cas los xij. Rau 30 m server-rau-hloov hop hauv ib kab ib kab, VCSEL-raws li multimode optics ntawm OM3 lossis OM4 feem ntau tsis tshua kim tshaj 1310 nm singlemode transceivers, thiab qhov sib txawv ntxiv sai sai hla ntau pua chaw nres nkoj.
OM1, OM2, OM3, OM4 thiab OM5 Fiber ntau yog dab tsi?
Tag nrho tsib qib OM yog multimode, tab sis lawv txawv ntawm qhov loj me, modal bandwidth thiab optics lawv tau tsim los ua haujlwm nrog. Qhov sib txawv ntawm OM1/OM2 (LED-era) thiab OM3/OM4/OM5 (laser-} optimized) yog qhov tseem ceeb tshaj plaws kom nkag siab.
OM1 (62.5/125 µm)
OM1 yog thawj 62.5 µm multimode fiber ntau uas khiav feem ntau xyoo 1990 thiab thaum ntxov -2000s enterprise LANs. Nws tseem txhawb nqa 1 Gigabit Ethernet tshaj 275 m ntawm 1000BASE-SX, tab sis ntawm 10G nws tsuas yog ncav cuag 33 m - luv luv rau feem ntau txoj hauv kev network tiag tiag. Yog tias koj pom OM1 hauv lub tsev ua haujlwm qub, nws feem ntau muaj kev nyab xeeb rau pob nyiaj siv rau OM4 tshiab dua li thawb 10G lossis siab dua ntawm cov nroj tsuag uas twb muaj lawm. Koj tseem tuaj yeem tau txais qhov chawOM1 62.5/125 thaj cordsrau legacy chaw nres nkoj hloov.
OM2 (50/125 µm)
OM2 poob cov tub ntxhais mus rau 50 µm thiab kwv yees li ob npaug ntawm cov qauv bandwidth piv rau OM1, tab sis nws predates laser optimization. Nws ua haujlwm 10GBASE-SR rau 82 m, uas yog txaus rau ntau hauv - khib thiab intra- kab txuas, tab sis nws tsis yog qhov zoo fiber ntau rau nruab rau hauv kev tsim tshiab.OM2 thaj cordsnyob twj ywm muaj txiaj ntsig thaum koj xav tau kev sib koom ua ke huv si nrog lub pob txha OM2 ntsia.
OM3 (Laser-zoo tshaj 50/125 µm)
OM3 yog thawj multimode fiber ntau engineered rau 850 nm VCSEL transceivers, nrog 2000 MHz ·km modal bandwidth. Nws ncav cuag 300 m ntawm 10G, 100 m ntawm 40GBASE-SR4 thiab 70 m ntawm 100GBASE-SR4. Rau cov ntaub ntawv luv luv kab thiab cov khoom siv-chav patching qhov twg 10G yog lub hom phiaj ntev -,OM3 thaj cordsfeem ntau yog tus nqi ntau tshaj - kev xaiv zoo.
OM4 (Laser - optimized 50/125 µm)
OM4 khaws tib yam 50/125 geometry thiab connector compatibility li OM3 tab sis ntau tshaj doubles modal bandwidth rau 4700 MHz ·km. Qhov tshwm sim yog 400 m ntawm 10G, 150 m ntawm 40G-SR4 thiab 100 m ntawm 100G-SR4. Rau qhov tshiab luv luv- ncav cuag kev tsim, tus nqi sib txawv ntawm OM3 thiabOM4 thaj cordsyog me me piv nrog rau kev ua haujlwm ntawm rub cable, yog li OM4 tau dhau los ua lub neej ntawd rau feem ntau cov ntaub ntawv niaj hnub chaw cabling.
OM5 (Wideband multimode)
OM5 tau tsim los rau Short Wavelength Division Multiplexing (SWDM), uas nqa plaub lub wavelengths los ntawm 850 nm mus txog 953 nm tshaj ib khub multimode. Nrog SWDM transceivers, OM5 ncav cuag tshaj OM4 - 150 m ntawm 100GBASE-SWDM4, piv txwv li - thiab quadruples muaj peev xwm tshaj tib lub fiber ntau suav. Tsis muaj SWDM optics, OM5 coj zoo li OM4. Tsis txhob them tus nqi OM5 tshwj tsis yog tias koj lub network tsim tau siv dav dav transceivers.

Yuav ua li cas xaiv ntawm Singlemode thiab Multimode Fiber
Ib qho yooj yim tsib- cov txheej txheem ua kom yuam kev xaiv feem ntau.
Kauj Ruam 1 - Paub meej qhov kev ncua deb
Qhov deb yog thawj lim. Yog tias qhov txuas yuav khiav ntawm ob lub tsev, hla ib lub tsev kawm ntawv, lossis raws txoj kev sib tham, OS2 yuav luag txhua lub sijhawm muaj kev nyab xeeb dua hu rau - thawb multimode ze rau nws qhov kev ncua deb noj rau hauv qhov txuas tsis siv nyiaj thiab tawm mus tsis muaj chaw rau kev hloov kho yav tom ntej. Nyob rau hauv ib lub tsev ntaub ntawv los yog chav tsev, OM3 los yog OM4 feem ntau yog txaus.
Kauj ruam 2 - Paub meej tias qhov yuav tsum tau ceev thiab lub qab ntug hloov dua siab tshiab
Yog tias qhov txuas hnub no yog 1G tab sis qhov hloov tshiab tom ntej yog 25G lossis 100G, tsim rau qhov nrawm tom ntej, tsis yog tam sim no. OM1 thiab OM2 poob luv luv ntawm 10G + hla qhov sib nrug tiag tiag; OM3 npog 10G yooj yim tab sis nruj ntawm 40G / 100G; OM4 yuav lub ntsiab lus headroom; OS2 npog txhua qhov Ethernet ceev tau teev tseg rau hnub tim.
Kauj Ruam 3 - Tshawb xyuas cov kab hluav taws xob uas twb muaj lawm
Ua ntej rov siv cov fiber ntau ntsia, xyuas:
- Fiber hom thiab cov tub ntxhais loj (OS2, OM1, OM2, OM3, OM4 lossis OM5).
- Hom Connector - LC, SC, ST, los yogMPO / MTP rau parallel optics.
- Polarity (A, B lossis C) rau kev sib txuas thiab kev sib txuas.
- Insertion poob thiab tag nrho cov peev nyiaj txuas, tau lees paub nrog OTDR lossis kev tso npe nkag -tsis tau kuaj.
- Xaus- lub ntsej muag mob - tshuaj xyuas txhua qhov chaw nres nkoj nrog lub fiber ntau ua ntej tig siab -speed optics.
Swapping transceivers yam tsis tau kuaj xyuas cov nroj tsuag yog feem ntau ua rau "qhov txuas yuav tsis tuaj" daim pib hauv cov cuab yeej cuab tam sib xyaw.
Kauj ruam 4 - Sib phim transceivers thiab connectors rau cable
Cable, connectors thiab optics yog ib qho system. 10GBASE-LR module xav tau ib hom fiber ntau; 10GBASE-SR module xav tau OM3 lossis zoo dua. A 40GBASE-SR4 lossis 100GBASE-SR4 module xav tau 8-fiber parallel MPO txuas. Ua ntej xaj fiber ntau, paub meej tias qhovhom transceiver, wavelength, connector interface, duplex-vim-parallel topology thiab tag nrho cov nyiaj txuas.
Kauj ruam 5 - Npaj rau kev hloov kho tshiab tom ntej
Qhov pheej yig tshaj cable niaj hnub no feem ntau tsis yog qhov pheej yig tshaj cable tshaj lub neej ntawm lub network, vim hais tias re- rub fiber ntau yog kim. Rau kev ua haujlwm multimode tshiab, OM4 feem ntau yog qhov kev nyab xeeb ntev dua - lub sij hawm thawj koom ruam dua OM3; rau txhua txoj hauv kev uas yuav muaj ib hnub yuav tsum tau loj hlob dhau ob peb puas meters, OS2 yog qhov kev xaiv tsim nyog los ntawm hnub ib.
Pom zoo Fiber los ntawm Daim Ntawv Thov
Enterprise LAN
Rau luv luv kab rov tav khiav hauv ib lub tsev, OM3 lossis OM4 yog qhov kev xaiv ib txwm muaj. Rau cov risers thiab inter- tsim kev sib txuas thoob plaws lub tsev kawm ntawv, OS2 yuav tsum nyob rau hauv kev tsim txawm tias multimode tau txais niaj hnub no.
Data center
OM4 yog qhov ua tau zoo rau luv luv - ncav cuag 10G, 25G, 40G thiab 100G hauv kab. OM5 yog tsim nyog qhia tsuas yog qhov twg SWDM los yog lwm yam wideband 850-953 nm optics yog ib feem ntawm lub network txoj kev npaj. Rau cov ntaub ntawv chaw sib cuam tshuam ntawm chav tsev lossis chaw, OS2 yog lub pob txha zoo.
Campus qaum
OS2 yeej ntawm kev ncua deb thiab yav tom ntej scalability. Multimode tseem tuaj yeem ua haujlwm rau luv luv intra- tsim cov risers, tab sis OS2 muab ntau lub taub hau rau ob qho tib si ncav cuag thiab muaj peev xwm loj hlob.
Telecom thiab ntev -haul
Singlemode nkaus xwb. Multimode tsis yog tsim los ntev -haul kis tau tus mob ntawm txhua qhov ceev.
Kev ruaj ntseg network qub
Tej zaum koj tseem yuav ntsib OM1 lossis OM2 hauv cov tsev qub. Txheeb xyuas cov fiber ntau uas twb muaj lawm ua ntej - pom nrawm ntawm lub tsho xim thiab cov tub ntxhais loj ntawm qhov txiav kawg feem ntau txaus - thiab tsuas yog tom qab ntawd npaj hloov pauv transceiver.
Koj puas tuaj yeem sib xyaw OS2, OM3, OM4 thiab OM5?
Cov lus nug txog kev sib raug zoo mus txog kev xa tawm ntau dua li ib qho kev xaiv tshwj xeeb.
Singlemode thiab multimode yeej tsis sib tov.Lub 9 µm OS2 core thiab 50 µm OM core muaj radically txawv hom profiles. Txuas lawv - txawm luv luv los ntawm ib qho adapter - ua rau muaj kev cuam tshuam loj heev thiab qhov txuas tsis ruaj khov. Ib txwm phim lub transceiver rau hom fiber ntau.
OM3 thiab OM4 yog lub cev sib xwsvim ob leeg siv 50/125 µm laser -optimized cores. Koj tuaj yeem ua phooj ywg lawv los ntawm tib lub LC lossis MPO connector, tab sis qhov txuas yuav ua tau qis dua ntawm ob qhov kev ntaus nqi. Rau ntev 40G lossis 100G khiav, khaws tag nrho cov channel ntawm OM4 lossis OM5.
OM5 yog rov qab sib xws nrog OM4rau tus qauv 850nm transceivers. OM5 qhov txiaj ntsig dav dav tsuas yog tshwm sim thaum SWDM lossis lwm yam ntau- wavelength multimode optics siv kawg rau qhov kawg.
OM1 / OM2 tov nrog OM3 / OM4 yuav tsum tau zamnyob rau hauv siab - txuas ceev. Lub 62.5 µm mus rau 50 µm core mismatch thiab LED-vim-VCSEL tso tawm qhov sib txawv tsim kev poob tsis tau.
Fiber xim codes thiab yuav ua li cas txheeb xyuas Cable uas twb muaj lawm
Jacket xim raws li nram noTIA-598-DCov rooj sib tham hauv ntau lub khw:
- OS2 singlemode - daj.
- OM1 thiab OM2 - txiv kab ntxwv.
- OM3 thiab OM4 - aqua (OM4 qee zaum zoo li erika violet los ntawm qee cov tuam ntxhab).
- OM5 - txiv qaub ntsuab.
Xim ib leeg tsis yog pov thawj ntawm fiber ntau pawg - qee qhov OM4 thaum ntxov tau raug xa mus rau hauv aqua zoo tib yam rau OM3, thiab kev hloov xim tshwm sim hauv kev kho. Thaum tsis ntseeg, nyeem lub tsho luam tawm, tshawb xyuas cov ntaub ntawv xa khoom, lossis ntsuas qhov txuas nrog OTDR.
Feem ntau yuam kev thaum xaiv Fiber Cable
Tsib yuam kev account rau feem ntau cov teeb meem teb:
- Piv txwv tias OM5 yeej zoo dua OM4.Tsis muaj SWDM optics, OM5 ua tau zoo li OM4 ntawm tus nqi siab dua.
- Xaiv ntawm kev ceev ib leeg thiab tsis quav ntsej kev deb.100GBASE-SR4 nce mus txog 70 m ntawm OM3 tab sis tsuas yog 100 m ntawm OM4 - txoj kev koj tuaj yeem tsim ntawm 70 m yuav ua tsis tiav ntawm 90 m.
- Kev sib xyaw fiber ntau ntawm tib lub siab -channel ceev.Khaws tag nrho qhov txuas ntawm ib hom fiber ntau, tshwj xeeb tshaj yog saum 10G.
- Ordering cable ua ntej lees paub optics thiab txuas pob nyiaj siv.Cov fiber ntau tsis tshua muaj qhov tsis ua haujlwm; lub transceiver -fiber- connector ua ke yog.
- Tsis nco qab lub tsho ntaus nqi.Plenum (CMP), riser (CMR), LSZH, sab hauv tsev - sab nraum zoov lossis armored yuav tsum tau hais los ntawm ib puag ncig kev teeb tsa, tsis yog qeb fiber ntau.
FAQ
Q: Puas yog OS2 zoo dua OM4?
A: Zoo dua yog txoj haujlwm- nyob ntawm. OS2 mus txog kilometers; OM4 yog pheej yig dua los txiav txim rau luv luv txuas vim VCSEL optics nqi tsawg dua 1310 nm singlemode lasers. Rau 50 m server txuas, OM4 yog qhov zoo dua; rau 2 km tsev kawm ntawv khiav, OS2 yog tib lub tswv yim teb.
Q: Kuv puas tuaj yeem txuas OS2 singlemode rau OM3 lossis OM4 multimode?
A: Tsis yog. Mating 9 µm singlemode rau 50 µm multimode ua rau qhov tsis txaus ntseeg thiab tsis ruaj khov ntawm lub xeev txuas. Cov hom fiber ntau tsis hloov pauv.
Q: Puas yog OM5 rov qab sib haum nrog OM4?
A: Yog, rau tus qauv 850 nm transceivers OM5 coj zoo li OM4. OM5 qhov txiaj ntsig dav dav tsuas yog tshwm sim nrog SWDM lossis zoo sib xws multi- wavelength multimode optics.
Q: Dab tsi fiber ntau zoo tshaj rau 10G Ethernet?
A: Rau kev txuas luv luv hauv ib lub chaw khaws ntaub ntawv, OM3 npog 300 m thiab OM4 npog 400 m ntawm 10GBASE-SR. Rau txhua yam ntev dua lossis rau txoj hauv kev ntawm cov tsev, xaiv OS2 nrog 10GBASE-LR lossis LR4 optics.
Q: Kuv puas yuav tsum siv OM3 lossis OM4 rau kev teeb tsa tshiab?
A: OM4 feem ntau. Tus nqi sib txawv me me piv rau kev teeb tsa ua haujlwm, thiab OM4 yuav lub taub hau muaj txiaj ntsig ntawm 40G thiab 100G.
Q: Dab tsi xim yog OS2, OM3, OM4 thiab OM5 fiber ntau?
A: OS2 yog daj, OM3 thiab OM4 yog aqua (OM4 qee zaus violet), OM5 yog txiv qaub ntsuab. Cov tsho OM1 thiab OM2 feem ntau yog txiv kab ntxwv.
Q: Puas tuaj yeem OM3 thiab OM4 thaj cords sib xyaw hauv tib lub channel?
A: Lub cev yog - ob leeg yog 50/125 µm - tab sis cov channel yuav ua tiav ntawm OM3 qhov ntsuas. Rau siab - nrawm nrawm txuas, khaws tag nrho txoj hauv kev ntawm OM4.
Kev Pom Zoo Kawg
- Xaiv OS2 rau qhov ntev -txoj kev sib txuas, lub hauv paus hauv tsev kawm ntawv, txoj hauv kev hauv xov tooj, cov ntaub ntawv chaw sib txuas, thiab txhua txoj hauv kev uas xav tau ntau xyoo ntawm lub taub hau.
- Xaiv OM4 raws li lub neej ntawd rau luv luv -mus txog cov ntaub ntawv chaw thiab kev lag luam multimode installation.
- Xaiv OM3 tsuas yog thaum qhov txuas yog luv luv thiab 10G yog qhov ntev - lub hom phiaj.
- Xaiv OM5 thaum SWDM lossis wideband multimode yog ib feem ntawm tus tsim.
- Khaws OM1 thiab OM2 hauv kev pabcuam nkaus xwb rau kev saib xyuas qub txeeg qub teg.
Txoj cai fiber ntau cable tsis yog qhov tshiab tshaj plaws lossis kim tshaj plaws. Nws yog lub cable uas nws cov tub ntxhais loj, modal bandwidth, connectors, lub tsho ntsuam xyuas thiab kev txhawb nqa nyob deb kab nrog cov transceivers thiab txuas pob nyiaj siv koj xav tau - hnub no thiab ntawm ob qhov kev hloov kho tom ntej.