Armored Simplex Fiber Patch Cord LC / APC Rau SC / APC, 2.5m, 2.0mm - Kev ruaj ntseg txee & khoom sib txuas

Xa kev nug
Armored Simplex Fiber Patch Cord LC / APC Rau SC / APC, 2.5m, 2.0mm - Kev ruaj ntseg txee & khoom sib txuas
Paub meej
2.0mm armored ib leeg -core fiber optic thaj qaum rau khib / khoom sib txuas, LC / APC-SC / APC kev txiav tawm, hais txog qhov tsis tshua muaj suab nrov thiab muaj zog tiv thaiv kev tiv thaiv, haum rau cov ntaub ntawv chaw, thaj vaj huam sib luag thiab FTTx txuas.
Kev faib tawm yam khoom
Fiber Cable Assemblies
Share to
Hauj lwm lawm

Txais tos mus yuav cov armored simplex fiber ntau thaj qaum lc/apc rau sc/apc, 2.5m, 2.0mm - ruaj ntseg txee & khoom interconnection nrog peb lub Hoobkas. Raws li ib qho ntawm cov ua lag luam thiab cov muag khoom nyob rau hauv Suav teb, peb kuj txais tos cov customized txiav txim. Tham tus nqi thiab cov lus hais nrog peb tam sim no.

 

Product Overview

Qhov no 2.5m armored ib leeg-core fiber optic thaj qaum nta LC/APC-SC/APC kev txiav tawm thiab 2.0mm sab hauv cov cuab yeej cuab tam, tsim los rau qis- kev sib cuam tshuam ntawm cov khoom siv, kho qhov muag modules, thiab thaj vaj huam sib luag nyob rau hauv cov neeg rau zaub mov racks. Cov ua tau - nyob rau hauv hlau armor txheej txhim khu kev tiv thaiv rau compression thiab hniav, ua rau nws haum rau congested los yog yooj yim hnav. APC endface pab txo cov ncha reflections, txhawb kev sib kis tau ruaj khov hauv PON / FTTx thiab cov ntaub ntawv chaw txuas.

 

Armored Simplex Fiber Patch Cord LC / APC rau SC / APC, 2.5m - Tech

Parameter Specification / Tus nqi Sau ntawv / Engineering Paub meej
Yam khoom Armored Stainle
Ntev 2.5 m Kev cai ntev muaj: 1m / 3m / 5m / 10m
Fiber suav 1 fiber ntau (Simplex) Duplex / multi{0}}core muaj nyob rau ntawm qhov kev thov
Cable Diameter 2.0mm ib Optimized rau siab - ceev txee routing
Connector A LC/APC Ua raws li IEC 61754-20
Connector B SC/APC Ua raws li IEC 61754-4
Hom Polish APC (8 degree) Kev xav rov qab qis rau siab - kev ua haujlwm network
Hom Fiber OS 2 9/125 μm Haum rau ntev - kis tau tus mob
Fiber Standard ITU-T G.657.A1 Rov qab siv tau nrog G.652.D, khoov- tsis pom kev
Ua haujlwm wavelength 1310/1550 nm Npog tus qauv telecom windows
Insertion Loss (IL) Tsawg dua los yog sib npaug rau 0.3 dB (Max) Yam tsawg dua los yog sib npaug rau 0.2 dB (qib hwm zoo xaiv tau)
Rov Los Loss (RL) Ntau dua lossis sib npaug li 60 dB Hom rau APC connectors
Yam tsawg kawg nkaus Khoov Radius Ntau dua lossis sib npaug li 40 mm (Long-term) Luv -Lub sij hawm Loj dua lossis sib npaug li 20 mm pom zoo
Tensile zog Ntau dua lossis sib npaug rau 100 N (Long-lub sijhawm) Txog li 200 N (lub sijhawm luv luv -)
Crush Resistance Ntau tshaj los yog sib npaug rau 1000 N / 100 mm Enhanced los ntawm armored qauv
Mating Durability Ntau tshaj lossis sib npaug rau 500 cycles Mus txog 1000 cycles (siab-qib connectors)
Jacket Khoom LSZH (Default) Yeem: PVC / OFNR / OFNP
Jacket Xim Dawb Kev cai xim muaj
Nplaim Retardancy IEC 60332-1: Cov Cov nplaim taws siab dua muaj nyob rau ntawm qhov kev thov
Haus luam yeeb ntom IEC 61034 (TSI) Cov pa luam yeeb tsawg
Halogen Cov ntsiab lus IEC 60754 (ib.) Halogen{0}}dawb
Ua haujlwm kub -25℃rau +70 degree Cia: -40℃rau +85 degree
Lub Hoobkas kuaj 100% IL / RL kuaj Cov ntawv xeem muaj nyob rau ntawm qhov kev thov
Xaus ntsej muag tshuaj xyuas IEC 61300-3-35: Cov Microscope soj ntsuam raws
Ua raws li RoHS / REACH Ua tau raws li cov qauv thoob ntiaj teb ib puag ncig
Ntim Ib lub hnab PE nrog daim ntawv lo OEM / kev cai ntim khoom muaj
Warranty 1-3 xyoos (Tshwj xeeb) Extended warranty muaj rau tej yaam num

 

Ntsiab nta & qhov zoo

Armored Protection rau kev txhim kho kev ntseeg siab

Cov khoom siv hlau sib xyaw ua ke (feem ntau stainless hlau raj) muab kev tiv thaiv zoo tshaj plaws rau kev sib tsoo, kev puas tsuaj, thiab kev puas tsuaj rau nas nyob rau hauv qhov chaw sab hauv tsev. Qhov no txo ​​qis txij nkawm ntau zaus thiab txo qhov kev pheej hmoo ntawm kev npaj txhij txog fiber ntau.

 

APC Polish rau qis -Reflection Performance

APC connector nta ib ~ 8℃angled kawg lub ntsej muag geometry kom txo qis rov qab xav. Nws yog qhov zoo tagnrho rau kev xav txog- cov ntawv thov nkag siab xws li PON, FTTx, thiab qee qhov sib txuas analog / RF kho qhov muag. Kev sib raug zoo (APC-rau-APC) ua kom muaj kev sib raug zoo network.

 

2.0mm Slim tsim rau siab -Density Cable Management

Lub 2.0mm cable txoj kab uas hla yog optimized rau ntom txee ib puag ncig, ua routing, bundling, thiab txij nkawm zoo dua. Nws txhim kho lub koom haum cable thaum tswj kev ua raws li kev pom zoo khoov vojvoog uas yuav tsum tau ua.

 

Factory Pre-Terminated and Tested for Consistency

Ua ntej- txiav tawm hauv qhov chaw tsim khoom tswj hwm, txhua lub xov tooj tau dhau los ua qhov poob thiab rov qab los xeem (kev tshuaj xyuas tag nrho lossis kev kuaj). Qhov no yuav txo tau ntawm - qhov chaw tsis paub meej thiab ua kom lub sijhawm xa mus sai.

 

Configurable Optical Performance Levels

Cov lus qhia tshwj xeeb muaj xws li Tsawg dua lossis sib npaug rau 0.3 dB qhov poob qis thiab Ntau dua lossis sib npaug rau 60 dB rov poob (APC). Rau siab dua - kev ua tau zoo, cov lus qhia nruj dua tuaj yeem ua tiav los ntawm cov txheej txheem txuas ntxiv polishing thiab tshuaj xyuas.

 

Cov qauv-Ua raws li kev sib koom ua ke tsis sib haum

Connector interfaces ua raws li IEC cov qauv (LC: IEC 61754-20, SC: IEC 61754-4), thaum kev sib koom ua ke ua raws li TIA-604 (FOCIS) cov qauv, kom ntseeg tau tias muaj kev sib raug zoo thoob plaws ntau lub network infrastructures.

 

Quantifiable Mechanical Reliability

Tsim los nrog kev ntsuas kev ua tau zoo, suav nrog Ntau dua lossis sib npaug rau 500 mating cycles thiab txhais lub vojvoog khoov (piv txwv li, Ntau dua lossis sib npaug li 40mm rau 2.0mm cable), ua kom pom tseeb cov qauv hauv kev yuav khoom thiab qhov project specifications.

 

Kev xaiv Jacket yooj yim rau qhov chaw sib txawv

LSZH cov ntaub ntawv tsho ua tau raws li IEC 60332, IEC 60754, thiab IEC 61034 tus qauv rau cov nplaim hluav taws kub, tsis muaj pa taws, thiab halogen- ua haujlwm dawb. Haum rau cov chaw zov me nyuam cov ntaub ntawv thiab ib puag ncig sab hauv tsev nrog cov kev cai nruj heev.

 

Vim li cas thiaj xaiv Armored Fiber Patch Cord dhau tus qauv?

Yam Tseem Ceeb Armored Simplex Fiber Patch Cord Standard Fiber Patch Cord
Mechanical Protection High (Stainless hlau armored txheej) Tsawg (Tsis muaj kev tiv thaiv txheej)
Khoov Resistance Strong (Resistant compression thiab dabtsi yog khoov) Tsis muaj zog (yooj yim cuam tshuam los ntawm kev ntxhov siab)
Kev ntseeg tau nyob hauv txee Tsim los rau siab - ib puag ncig ceev Tsis pom zoo rau txoj kev nruj
Risk ntawm Fiber puas Tsawg heev Siab nyob rau hauv complex ib puag ncig
Kev tu ntau zaus Lower (Lub neej ua haujlwm ntev) Siab dua (Ntau zaus hloov)
Cable Management Optimized 2.0mm rau ntom routing Feem ntau 3.0mm, tsis hloov pauv hauv qhov chaw nruj
Installation Efficiency Kev xa tawm ncaj qha, tsawg dua kev ua tsis tiav Tej zaum yuav xav tau kev rov ua haujlwm lossis kev tiv thaiv
Daim ntawv thov Scenario Txee, cov chaw khaws ntaub ntawv, cov khoom siv hauv xov tooj Chaw ua haujlwm, tsawg-kev pheej hmoo nyob hauv tsev

 

Cov lus nug nquag

Dab tsi yog armored fiber thaj qaum thiab vim li cas nws siv hauv cov khoom?

Lub armored fiber ntau thaj qaum nta cov hlau tiv thaiv txheej uas tiv thaiv kev puas tsuaj los ntawm dabtsi yog khoov, compression, thiab tuav. Nws yog qhov zoo tagnrho rau kev sib txuas hauv txee qhov twg cov cables raug rau cov neeg kho tshuab kev ntxhov siab thiab xav tau kev ntseeg siab dua.

 

Vim li cas ho xaiv armored simplex fiber thaj qaum es tsis txhob ntawm tus qauv?

Armored simplex fiber thaj cords muab kev ruaj khov thiab kev tiv thaiv zoo dua, txo qhov kev pheej hmoo ntawm fiber ntau tawg. Qhov no ua rau cov nqi kho mob qis dua thiab kev ua haujlwm ruaj khov hauv lub network hauv siab - qhov chaw ntom ntom.

 

Puas yog 2.0mm armored fiber ntau thaj cord haum rau siab -density cabling?

Yog lawm. Tus tsim 2.0mm tso cai rau kev yooj yim dua thiab kev tswj cov kab hluav taws xob zoo dua hauv cov txee, ua rau nws xaiv qhov chaw zoo dua - txwv thiab siab - kev xa tawm ceev.

 

Dab tsi yog qhov txiaj ntsig ntawm LC / APC rau SC / APC fiber ntau thaj qaum?

Qhov kev teeb tsa no tso cai rau kev sib txuas ncaj qha ntawm qhov sib txawv interfaces yam tsis muaj kev hloov pauv, txo qis kev poob thiab yooj yim teeb tsa hauv kev siv xov tooj thiab FTTx.

 

Vim li cas APC connectors nyiam nyob rau hauv fiber optic networks?

APC connectors txo qhov kev xav rov qab (Ntau dua lossis sib npaug li 60 dB), ua kom cov teeb liab ruaj khov. Lawv tau siv dav hauv PON, FTTx, thiab lwm yam kev xav txog -sensitive networks.

Cim npe nrov: armored simplex fiber ntau thaj qaum lc/apc rau sc/apc, 2.5m, 2.0mm - ruaj ntseg txee & khoom interconnection, Tuam Tshoj, Hoobkas, lwm tus neeg, manufacturers, hais, customized, nqe, yuav

Xa kev nug