FOCC MMC-16 Fiber Optic Jumper yog ultra-compact, siab-kev ua tau zoo cable tsim los rau tiam tom ntej 400G/800G optical interconnects.
Kev faib tawm yam khoom
MPO MTP Khawm Cable
Share to
Hauj lwm lawm

Txais tos muas lub mmc-16 fiber optic jumper|vsff high-density 16-fiber thaj qaum rau 400g / 800g cov chaw zov me nyuam nrog peb lub Hoobkas. Raws li ib qho ntawm cov ua lag luam thiab cov muag khoom nyob rau hauv Suav teb, peb kuj txais tos cov customized txiav txim. Tham tus nqi thiab cov lus hais nrog peb tam sim no.

 

Kev piav qhia

CovFOCC MMC-16 Fiber Optic Jumperyog ib qho ultra-compact, siab-kev ua tau zoo cable tsim rau tom ntej- tiam400G / 800G optical interconnects.
Nruab nrogUS Conec MMC connectorsntawm ob qhov kawg, qhov no VSFF jumper triples qhov chaw nres nkoj ceev piv rau ib txwm siv MPO / MTP systems thaum tswj hwm qhov tshwj xeeb kho qhov muag.
Featuring lubDirectConec thawb- rub khau raj, nws ua kom tsis muaj zog ua haujlwm hauv qhov chaw nruj. Kev siv ntawmTMT Elite ferrule technologyguarantees qis insertion poob thiab siab rov qab poob nyob rau hauv ob qho tib siOM4 multimode (Magenta)thiabOS2 single-mode (daj)txawv.
Engineered rau kev ntseeg siab, scalability, thiab kev nyab xeeb, MMC-16 jumpers redefine ceev thiab efficiency nyob rau hauv niaj hnub data center cabling.

 

MMC-16 Fiber Jumper

APPLICATIONS

● 400G/800G parallel kis systems siv QSFP-DD, OSFP, lossis DR8 modules.

● High-ntaus qauv cabling nyob rau hauv hyperscale thiab enterprise cov ntaub ntawv chaw.

● Inter-rack lossis intra- khib patching rau modular panels thiab cassettes.

● Chaw-kev txwv ib puag ncig yuav tsum tau ultra-compact VSFF connectors.

● Telecom thiab caj qaum kho qhov muag txuas hauv cov ntaub ntawv ntse.

● Kev sim thiab R&D cov chaw kuaj mob yuav tsum tau rov ua tau siab -kev sib txuas qhov muag pom tseeb.

 

NTAUB NTAWV

● Daim ntawv me me heev (VSFF) MMC connector muaj 3 × qhov chaw nres nkoj ceev ntawm MPO.

● DirectConec thawb- rub khau raj enables cuab tam - pub dawb tso thiab rho tawm.

● TMT Cov Neeg Tseem Ceeb ferrule lav Tsawg dua lossis sib npaug ntawm 0.35 dB qis qis qis thiab siab APC rov qab poob.

● Tau tshaj MT / MT-16 mechanical alignment structures.

● Muaj nyob rau hauv OM4 (Multimode) thiab OS2 (Ib leeg-Hom) fiber ntau hom.

● Plenum (OFNP) nplaim taws-cov tsho tiv thaiv kom siv tau zoo hauv huab cua- tuav qhov chaw.

● Lub teeb yuag 2.5 hli khoov-sensitive fiber ntau nrog 7.5-10 hli qhov qis qis qis.

● Lub Hoobkas ua ntej- txiav tawm thiab 100% IL/RL tau sim rau kev ua haujlwm zoo ib yam.

 

Feature Paub meej

MMC-16 Fiber Jumper

 

1.VSFF Ultra-Compact Interface
MMC connector's 3 × siab dua qhov chaw nres nkoj tso cai ntau fibers rau ib chav tsev khib, ua tiav kev siv ntau tshaj plaws ntawm qhov chaw txwv txee.

2.DirectConec Push-Pull Boot
Ib qho kev hloov pauv hloov pauv uas ua rau ib qho - muab tso rau hauv thiab tshem tawm, ua kom yooj yim nkag mus rau hauv siab - ntom ntom pem hauv ntej vaj huam sib luag.

3.TMT Elite Ferrule Precision
Ua kom muaj kev lag luam- ua qhov raug kho qhov muag nrog tsawg dua lossis sib npaug li 0.35 dB qhov poob thiab qhov tshwj xeeb APC rov qab poob mus txog 60 dB.

4.Dual-Mode Compatibility
OM4 multimode txhawb siab- nrawm nrawm- ncav cuag kis tau tus mob; OS2 ib leeg-mode muab ntev-nqe deb- tsis ua haujlwm.

5.Bend-Insensitive thiab Rugged Design
Engineered nrog BIF thiab G.657.A1 fibers los tswj cov teeb liab kev ncaj ncees nyob rau hauv nruj khoov thiab nquag tuav.

6. Hluav taws kub-Kev nyab xeeb thiab siv tau yooj yim
Plenum (OFNP) lub tsho ua tau raws li cov cai nruj kev nyab xeeb thaum tswj kev yoog raws thiab yooj yim routing.

7.Factory-Terminated Reliability
Txhua lub rooj sib txoos ua tiav 100% IL / RL kev sim thiab tshuaj xyuas, kom ntseeg tau tias kev xa tawm ruaj khov.

 

Khoom Specifications

Parameter Kev piav qhia
Connector A US Conec MMC Poj Niam (Pinless)
Connector B US Conec MMC Poj Niam (Pinless)
Hom Polish PC/UPC (OM4), APC lossis UPC (OS2)
Hom Fiber OM4 50/125 μm (Multimode) / OS2 9/125 μm (Ib leeg-Mode)
Lub wavelength 850/1300nm (OM4) / 1310/1550nm (OS2)
Fiber suav 16 Fibers
iav Fiber Khoov-Insensitive (OM4) / G.657.A1 (OS2)
Cable Diameter 2.5 hli
Cable Jacket Plenum (OFNP)
Polarity Configurable rau ib daim ntawv thov (Hom A / Hom B / Hom C)
Yam tsawg kawg nkaus Khoov Radius 7.5mm (OM4) / 10mm (OS2)
Insertion Loss Tsawg dua lossis sib npaug rau 0.35 dB (Max)
Rov Los Los Ntau dua lossis sib npaug li 40 dB (OM4) / Ntau dua lossis sib npaug rau 60 dB (OS2 APC)
Attenuation @ 850 nm Tsawg dua lossis sib npaug li 3.5 dB / km
Attenuation @ 1300 nm Tsawg dua lossis sib npaug li 1.5 dB / km
Attenuation @ 1310 nm Tsawg dua lossis sib npaug li 0.4 dB / km
Attenuation @ 1550 nm Tsawg dua lossis sib npaug li 0.3 dB / km
Tensile zog 30 N (Lub Sij Hawm Ntev) / 100 N (Lub Sij Hawm Luv)
Ua haujlwm kub −10℃~ +60 degree
Cia Kub −10℃~ +70 degree
Durability Ntau tshaj los yog sib npaug rau 500 mating cycles

 

Daim ntawv thov Paub meej

MMC 16 Patch Cord

 

● Cov Chaw Cov Ntaub Ntawv- Pab kom ultra{0}}dense patching rau 400G/800G infrastructure.

● Huab & HPC Systems- Ua kom zoo dua GPU pawg sib cuam tshuam thiab fiber ntau txoj hauv kev.

● Cov Khoom Siv Hauv Xov Tooj- Muab kev sib cog lus, txhim khu kev qha fiber ntau ntawm ODF units.

● Enterprise Networks- Ua kom yooj yim cov txheej txheem cabling thaum txhawb kev scalability yav tom ntej.

● Kev Xeem & R & D Labs- Muab qhov rov ua tau dua thiab siab - qhov tseeb qhov kev sib tw kho qhov muag.

 

FAQ

MMC connector yog dab tsi?
Lub MMC yog ib daim ntawv me me heev (VSFF) txuas los ntawm US Conec uas muab 3 × qhov chaw nres nkoj ceev ntawm cov tsoos MPO interfaces.

Dab tsi yog qhov txawv ntawm OM4 thiab OS2 versions?
OM4 yog multimode fiber ntau rau luv luv - ncav cuag, siab -bandwidth txuas, thaum OS2 yog ib qho - hom fiber ntau rau kev sib kis ntev - deb.

Qhov no puas siv tau nrog MTP / MPO connectors?
Tsis ncaj. MMC thiab MPO siv sib txawv interfaces, tab sis hybrid MMC - mus rau -MTP cables muaj nyob rau hauv daim ntawv thov tsiv teb tsaws.

Dab tsi yog qhov raug ntxig thiab rov qab poob?
Insertion poob Tsawg dua lossis sib npaug rau 0.35 dB (max) thiab rov qab poob Ntau dua lossis sib npaug li 40-60 dB nyob ntawm hom fiber ntau thiab polish.

Kuv puas tuaj yeem xaj qhov ntev lossis xim?
Yog lawm. Ntev, xim (Magenta, Daj, Aqua thiab lwm yam), thiab daim ntawv lo tuaj yeem ua raws li koj qhov yuav tsum tau ua.

Qhov ntsuas lub tsho dab tsi nws siv?
Plenum (OFNP), ua raws li cov qauv kev nyab xeeb hauv tsev rau kev nyab xeeb ntawm huab cua sab hauv- chaw tuav.

Puas yog HOLIGHT muab kev pabcuam OEM / ODM?
Yog lawm. Peb muab kev xaiv OEM / ODM nrog rau kev luam ntawv logo, daim ntawv lo ntiag tug, thiab ntim tshwj xeeb.

Yuav ua li cas txhua jumper kuaj ua ntej xa zaub mov?
Txhua lub rooj sib dhos yog ib tus zuj zus sim rau qhov poob, rov qab poob, thiab pom qhov kawg -kev tshuaj xyuas lub ntsej muag kom ntseeg tau tias kev ua haujlwm zoo ib yam.

 


 

Cov ntsiab lus tseem ceeb

MMC-16 Fiber Jumper, VSFF High-Density Patch Cord, 16-Fiber Cable OM4 OS2, APC Tsawg-Poob Jumper, DirectConec Push-Pull Connector, TMT Elite Ferrule, OFNP PlenumG5 MC Cable, Fiber. Jumper, High-Density Data Center Interconnect

 

Daim ntawv pov thawj zoo

Kev ua tau zoo thiab cov qauv yog lub hauv paus ntawm FOCC. Peb mob siab rau muab cov neeg siv khoom zoo tshaj plaws, cov qauv- cov khoom lag luam thiab cov kev pabcuam ua raws.
FOCC tau dhau ntau qhov kev pov thawj zoo, xws li CE, RoHS, tau tsim ib qho kev lees paub zoo thoob ntiaj teb thiab ua raws li kev tswj hwm thiab kev tswj hwm nruj me ntsis hauv kev tsim, kev tsim, kev tsim, kev teeb tsa thiab kev pabcuam.

Thov nco ntsoov: Txhua qhov fiber ntau thaj cable yog 100% optically tshuaj xyuas thiab kuaj xyuas qhov poob ua ntej koj tau txais.

 

High Quality Fiber Optic Cable Guarantee

Peb lees txais 100% kev soj ntsuam zoo, yog tias muaj teeb meem zoo tom qab xa khoom, peb yuav npaj rov qab los yog rov qab them tag nrho ASAP!

 