
Multi-fiber Push-Ntawm cov connectors tau hloov pauv cov ntaub ntawv chaw cabling topology. IbMPO-rau-MPO kev sib txuas-qhov tseem ceeb txuas ob ntau -fiber array interfaces ncaj qha- ua haujlwm raws li cov pob txha caj qaum rau kev sib txuas ntawm optics thiab siab - lub cev ceev routing. Tsis zoo li ib txwm duplex LC lossis SC kev sib txuas uas ua haujlwm ib khub fiber ntau, MPO interfaces sib sau ua ke 8, 12, 16, lossis txawm tias 24 fiber ntau rau hauv kev sib koom ua ke ferrule, ua rau tib lub sijhawm ntau cov ntaub ntawv xa tawm raws li IEEE 802.3 tus qauv rau 40}GBASE{{12} 100GBASE-SR4, thiab tawm 400G specifications.
Parallel Optics Situation
Ntawm no yog qhov uas cov khoom tau nthuav tawm -thiab ua siab ncaj, me ntsis counterintuitive yog tias koj los ntawm legacy duplex cabling.
Kev sib txuas ntawm fiber ntau ua haujlwm ntawm lub hauv paus ntsiab lus yooj yim: ib txoj hlua xa mus, lwm qhov tau txais. huv. Elegant. Tab sis thaum network architects pib thawb mus rau 40 Gigabit thiab 100 Gigabit speeds, lub physics tau nyuaj. Kev tsim kho qhov muag uas hloov thiab tawm 40 billion zaug hauv ib ob? Txwv tsis pub kim. Qhov kev ua haujlwm tau ntse: tsis yog ib qho blazing- channel ceev, siv ntau txoj kab qeeb khiav ib txhij.
40GBASE-SR4 faib cov tsheb khiav hla plaub txoj kab 10G. 100GBASE-SR4 ua tib yam nrog plaub txoj kab 25G. Txhua txoj kab xav tau nws tus kheej xa tawm thiab tau txais fiber ntau. Qhov ntawd yog yim fibers yam tsawg kawg nkaus rau ib qho kev sib txuas siab - nrawm. Mam li nco dheev, cov qub LC patch cords zoo li tsis txaus.
MPO-rau-MPO kev sib txuas tau dhau los ua qhov kev daws teeb meem pom tseeb. Plug ib qho 12-fiber lossis 8-fiber MPO lub cev ncaj qha ntawm ob lub SR4 transceivers, thiab koj tau txais koj qhov sib npaug optics channel tsim. Tsis muaj kev hloov dua siab tshiab modules, tsis muaj fanout hassles-tsuas yog kev sib txuas ncaj qha.
Backbone Trunk Deployments
Feem ntau cov chaw tswj xyuas cov ntaub ntawv ntsib MPO-rau-MPO kev sib txuas ua ntej hauv daim ntawv thov pob txha, txawm tias ua ntej qhov sib txuas optics nkag mus rau hauv daim duab.
Qhov xwm txheej feem ntau nthuav tawm zoo li qhov no: koj tab tom khiav 10 Gigabit Ethernet hla koj qhov chaw, siv cov pa LC duplex txhua qhov chaw. Tab sis txoj kev cable tau txais congested. Khiav rau caum tus neeg duplex cables nruab nrab ntawm cov chaw faib khoom siv txoj hauv kev, cuam tshuam rau kev tswj hwm cable, tsim teeb meem airflow. Ib tug neeg qhia kom sib sau ua ke rau hauv MPO lub cev cables.
Ib qho 24- fiber ntau MPO pob tw hloov kaum ob cais duplex khiav. Ntawm cov ntsiab lus txiav tawm, MPO-rau-LC cassettes lossis fanout modules tawg rau ib tus neeg sib txuas rau koj cov khoom siv 10G. Lub nraub qaum nws tus kheej- qhov kev tsim kho tseem ceeb ntawm thaj chaw faib khoom loj thiab thaj chaw kab rov tav- tseem nyob MPO- rau-MPO thoob plaws.
Qhov no tsis yog tsuas yog kev huv si rau nws tus kheej. Ua ntej- txiav MPO cov rooj sib tham siv sai dua li qhov chaw- txiav tawm lwm txoj kev. Factory- polished kawg ntsej muag feem ntau ua tiav 0.35 dB qhov poob lossis zoo dua, piv rau cov txiaj ntsig sib txawv uas koj tau txais los ntawm cov kws tshaj lij ua haujlwm hauv cov chaw qab nthab.

Thaum Direct MPO-rau-MPO Tiag Tiag
Tsis yog txhua qhov kev xa tawm tau lees paub txoj hauv kev no, thiab kuv tau pom ntau qhov kev teeb tsa uas MPO tau siv ... cia peb hais kom txaus siab ...
Direct MPO-rau-MPO kev sib txuas ua haujlwm zoo tshaj plaws thaum:
- Koj cov khoom siv ib txwm txhawb nqa MPO interfaces.Niaj hnub nimno QSFP+, QSFP28, thiab QSFP-DD transceivers feem ntau muaj MPO receptacles. Txuas 40G hloov mus rau lwm qhov hloov 40G? Khiav ib lub cev MPO ncaj nruab nrab ntawm lawv. Lub 40GBASE-SR4 optics ntawm txhua qhov kawg xaus rau hauv 12- fiber MPO (txawm tias tsuas yog 8 fibers tau siv tiag tiag- txoj haujlwm 5-8 tseem tsaus). Ib hom B polarity lub cev nrog cov khoom sib txuas tseem ceeb ntawm ob qhov kawg ua rau cov fiber ntau thim rov qab.
- Cov kev xav tau ceev xav tau kev sib koom ua ke.Lub 1U thaj vaj huam sib luag haum 72 fibers ntawm MPO siv tib qhov chaw raws li ib tug tuav 24 fibers ntawm LC. Nyob rau hauv ib puag ncig hyperscale qhov twg txhua chav tsev suav suav, qhov ntom ntom kom zoo dua qhov sib txuas ntawm ntau txhiab kev sib txuas.
- Kev npaj tsiv teb tsaws chaw pom zoo rau kev nqis peev ua ntej.Nov yog lub tswv yim lub tswv yim: xa 12-fiber MPO trunks hnub no rau koj 10G LC connectivity ntawm cassettes. Thaum qhov kawg 40G lossis 100G kev hloov kho tuaj txog, hloov cov cassettes rau MPO adapter panels thiab txuas koj cov khoom siv SR4 ncaj qha. Cov kab mob qaum qaum tseem nyob tsis tau.
Tab sis khiav MPO-rau-MPO ntawm ob lub cuab yeej uas hais lus LC? Qhov ntawd yuav tsum tau hloov dua siab tshiab kho vajtse ntxiv -cassettes, harness cables- ntxiv qhov poob thiab nqi. Qee zaum cov pa duplex ua rau muaj kev nkag siab ntau dua.
Polarity: Tus kws tsim teeb meem ntsiag to
Kuv yuav tsum hais txog polarity vim tias nws mus txog kev teeb tsa ntau dua li cov neeg lees paub.
MPO connectors nqa ntau fibers nyob rau hauv tas li txoj hauj lwm. Txoj hauj lwm 1 ntawm ib qho kawg yuav tsum txuas mus rau txoj haujlwm tsim nyog ntawm lwm qhov kawg raws li koj txoj kev xav polarity. Muaj peb txoj hauv kev (Hom A, Hom B, Hom C), txhua tus siv cov kab sib txawv thiab cov kev taw qhia tseem ceeb.
Hom B dominates parallel optics deployments. Cov haujlwm fiber ntau thim rov qab kawg-rau- kawg: txoj hauj lwm 1 tuaj txog ntawm txoj hauj lwm 12, txoj hauj lwm 2 ntawm txoj hauj lwm 11, thiab lwm yam. Qhov no tshwm sim vim hais tias ob qho tib si connectors mount yuam sij -up, nrog rau reversal tshwm sim nyob rau hauv lub cable nws tus kheej.
Hom A siv ncaj nraim - los ntawm txoj hauv kev nrog tus yuam sij - nce ntawm ib kawg thiab tus yuam sij - nqes ntawm lwm qhov. Ua haujlwm zoo rau kev siv duplex breakout siv cov cassettes, tab sis txuas SR4 transceivers ncaj qha? Koj yuav xav tau hom B thaj qaum ntawm ib kawg los kho qhov polarity.
Qhov kev ntxhov siab: koj tuaj yeem ua tus khub mismatched polarity cables yam tsis muaj qhov pom tseeb tias muaj qee yam tsis raug. Cov connectors nyem ua ke txaus siab. Tom qab ntawd koj cov kev sib txuas tsis ua haujlwm lossis koj txoj kab sib tw, thiab kev daws teeb meem pib.
Cov qauv txuas tshiab dua tshiab xws li US Conec's MTP Elite Pro tso cai rau kev hloov pauv hloov pauv hloov pauv siv cov cuab yeej yooj yim- tsawg kawg rau kev siv ntau hom. Singlemode APC connectors tsis tuaj yeem hloov pauv vim yog lub kaum sab xis.

400G thiab Tshaj Tawm: Fiber suav nce ntxiv
Kev hloov mus rau 400 Gigabit Ethernet tau qhia txog 16-fiber MPO connectors rau cov ntsiab lus tseem ceeb ntawm cov ntaub ntawv chaw.
400GBASE-SR8 ua haujlwm hla yim txoj kab sib txuas ntawm 50G txhua. Yim xa cov fibers, yim tau fibers- kaum rau tag nrho. Cov kev sib txuas hneev taw tseem nyob sib npaug li ib txwm 12-fiber MPO, tsuas yog nrog ib kab ntawm 16 fibers ntau dua li 12.
Kev taw qhia tseem ceeb sib txawv ntawm 12-fiber thiab 16-fiber MPO variants tshwj xeeb los tiv thaiv kev tsis sib haum xeeb. Cov ntsiab lus me me, cuam tshuam loj.
Rau 400GBASE-DR4 tshaj singlemode, cov qauv hloov dua tshiab. Plaub txoj kab ntawm 100G txhua, siv PAM4 kev hloov kho, tsuas yog yuav tsum muaj yim fibers. Tab sis cov kev sib txuas no tswj hwm lub cev sib tiv tauj (APC) polish los tswj kev rov qab poob ntawm qhov teeb meem siab dua. Cov khoom sib txuas tseem yog 12-fiber MPO vaj tsev, nrog rau txoj haujlwm 5-8 tsis siv, tab sis lub kaum sab xis APC ntxiv lwm qhov kev xav tau sib xws.
800G kev xa tawm twb tau tshwm sim nyob rau hauv kev ua - ntug kev teeb tsa, thawb mus rau 16-fiber MPO raws li tus qauv thiab tshawb nrhiav heev-me- daim ntawv-factor (VSFF) txuas zoo li Senko's SN-MT kom muaj qhov ntom ntom dua.
Installation Realities
Txoj kev xav hnov huv si. Kev xyaum tau messier.
MPO kev sib txuas xav tau obsessive huv. Ib qho kab mob sib kis ntawm ib qho fiber ntau hauv 12-fiber array tuaj yeem degrade lossis tawg txoj kab kev sib txuas. Tsis zoo li duplex connectors qhov twg koj tab tom tshuaj xyuas thiab ntxuav ob lub ntsej muag fiber ntau, MPO yuav tsum tau tshuaj xyuas kaum ob lossis ntau dua-zoo dua nrog lub tshuab tsom iav tsim rau kev tshuaj xyuas array.
"Trust but verify" siv ntawm no. Ntxuav lub connector. Tshawb xyuas nws. Feem ntau, koj yuav pom thawj qhov kev tshem tawm cov khib nyiab es tsis muab tshem tawm. Ntxuav dua. Re- tshuaj xyuas. Tsuas yog mate qhov kev sib txuas ib zaug koj tau lees tias txhua txoj haujlwm fiber ntau yog qhov tseeb.
Kev sib yuav nws tus kheej yuav tsum tau saib xyuas poj niam txiv neej. Txiv neej MPO connectors nqa alignment pins; poj niam connectors muaj qhov sib thooj. Kev sim ua phooj ywg ob tus poj niam txuas los ntawm lub adapter ua rau tsis muaj lub teeb kis tau tus mob- lub ntsej muag ferrule kawg tsis tau ua tiav lub cev sib cuag yam tsis muaj tus pins yuam kev sib tw. Kuv tau saib cov kws paub txog kev paub ua qhov yuam kev no, ua rau xav tsis thoob vim li cas lawv qhov txuas "txuas" tsis pom muaj teeb liab dab tsi.
Transceivers feem ntau muaj txiv neej (pinned) receptacles, expecting poj niam thaj qaum los yog lub cev cables. Cov kab hluav taws xob feem ntau khiav poj niam-rau- poj niam, vam khom txiv neej-rau- txiv neej adapter vaj huam sib luag ntawm cov ntsiab lus txiav. Tab sis txhua tus neeg muag khoom siv qhov sib txawv me ntsis, thiab kev xav txog poj niam txiv neej tuaj yeem cuam tshuam tag nrho cov kev teeb tsa yog tias hom cable tsis raug tuaj txog ntawm qhov chaw.
Poob peev nyiaj tau nruj
Parallel optics channels ua haujlwm raws li kev siv nyiaj poob qis . 100GBASE-SR4 tso cai kwv yees li 1.9 dB tag nrho cov channel poob rau 100-meter ncav cuag OM4 multimode fiber ntau.
Txhua MPO mating pab txhawb qhov nruab nrab ntawm 0.20 dB (rau cov neeg tseem ceeb / qis- cov khoom sib txuas) thiab 0.75 dB (rau cov qauv txuas, ib qho chaw tsim khoom specs). Ib qho chaw nruab nrab cov ntaub ntawv yuav suav nrog plaub qhov sib txuas sib txuas ntawm lub ntsej muag transceiver. Nrog cov qauv sib txuas, koj tau haus 3 dB tsuas yog ntawm kev sib txuas - dhau koj cov peev nyiaj tag nrho ua ntej fiber ntau attenuation txawm tias nyob rau hauv.
Qhov no yog vim li cas qis - poob MPO Cheebtsam muaj nyob thiab vim li cas lawv thiaj li tsim nyog tus nqi hauv siab - daim ntawv thov ceev. MTP Cov neeg tseem ceeb connectors los ntawm US Conec qhia 0.35 dB qhov siab tshaj plaws random mated poob, nrog rau cov nqi ib ncig ntawm 0.15-0.20 dB. Kev ua haujlwm siab ntev yog nruj dua: zoo dua ferrule geometry, ntau cov fiber ntau protrusion siab, nruj dua kev tswj xyuas.
Rau 40G daim ntawv thov nrog ntev mus txog pob nyiaj siv, cov qauv txuas yuav txaus. Rau 100G los ntawm ntau lub vaj huam sib luag, thiab tshwj xeeb tshaj yog rau kev xa tawm 400G, qhia qis- poob thoob plaws hauv cov channel tsis yog xaiv tau- nws yog lej lej.

Kev txiav txim siab Singlemode
Feem ntau MPO-rau-MPO kev sib tham tsom mus rau multimode parallel optics, tab sis cov ntawv thov singlemode muaj thiab loj hlob.
400GBASE-DR4 khiav plaub 100G PAM4 channels hla singlemode fiber ntau ntawm qhov deb mus txog 500 meters. Cov khoom sib txuas yog 12- fiber ntau MPO nrog APC polish. Yim- fiber ntau variants muaj rau cov ntawv thov xws li 100GBASE-PSM4.
Singlemode MPO xav tau txawm tias nruj dua qhov ntev dua li multimode. Cov me me fiber ntau cores (9 microns piv rau 50 microns rau OM4) tawm tsawg dua rau qhov kev ua yuam kev. Insertion poob specifications nruj raws li.
Thiab APC lub kaum sab xis ntxiv qhov nyuaj. Koj tsis tuaj yeem ua tus khub APC txuas rau UPC connector- lub kaum sab xis thiab lub ntsej muag tiaj tus yuav tsis ua kom zoo, ua rau poob siab thiab muaj peev xwm puas tsuaj. Cable thiab khoom siv daim ntawv lo yuav tsum qhia meej txog APC piv rau UPC, thiab kev yuav khoom yuav tsum qhia kom raug. Tau txais qhov tsis ncaj ncees lawm txhais tau tias siv tsis tau cables thiab kev txiav txim hloov sai.
Kev xam nyiaj txiag
MPO infrastructure raug nqi ntau dua li qhov sib npaug duplex xa tawm. Cov connectors yog kim dua. Cov cuab yeej xeem yog tshwj xeeb. Cov cuab yeej tu txawv.
Tab sis kev teeb tsa kev ua haujlwm poob qis heev nrog ua ntej- txiav MPO cov rooj sib tham piv rau teb- txiav cov kab hluav taws xob duplex. Kev siv cov kab hluav taws xob zoo dua. Yav tom ntej migration muaj peev xwm muab kev xaiv tus nqi.
Kev suav yog nyob ntawm qhov ntsuas. Ib lub lag luam me me nrog nees nkaum 10G txuas tej zaum tsis ua rau MPO infrastructure. Lub chaw hyperscale cov ntaub ntawv xa tawm ntau txhiab txhiab ntawm 100G kev sib txuas tsis muaj lwm txoj hauv kev.
Qee qhov ntawm cov kev kub ntxhov no yog ib qho kev sib tw uas nyob ntawm koj cov nqi zog, kev txwv txoj hauv kev, kev loj hlob, thiab kev pheej hmoo rau kev cuam tshuam rau kev tsiv teb tsaws chaw. Cov lus teb ncaj ncees yog: nws txawv.
Kev taw qhia tswv yim (Thaum kawg)
Yog tias koj siv 40G, 100G, lossis 400G parallel optics, MPO-rau-MPO kev sib txuas yog qhov tseem ceeb. Cov transceivers xav tau lawv.
Yog tias koj tab tom ua haujlwm siab -nruab qaum qaum cabling thiab cia siab tias yuav muaj kev sib txuas ntawm optics nyob rau hauv cov txheej txheem kev ua neej nyob (feem ntau yog 15+ xyoo rau kev tsim cabling), MPO trunks nrog cassette breakouts muab ib tug sensible architecture.
Yog tias koj tab tom txuas tus lej me me ntawm qis dua - kev sib txuas ceev uas tsis muaj txoj hauv kev tsiv teb tsaws chaw nyob rau hauv qhov pom, cov pa duplex tej zaum yuav ua haujlwm zoo dua. MPO infrastructure qhia txog qhov nyuaj uas yuav tsum tau ua kom ncaj ncees los ntawm qhov ceev, kev ua tau zoo, lossis cov txiaj ntsig kev tsiv teb tsaws chaw.
Thaum qhia txog MPO-rau-MPO:
Paub meej tias cov fiber ntau suav nrog koj daim ntawv thov . 8-fiber rau qee daim ntawv thov 40G BiDi. 12-fiber rau SR4 thiab feem ntau cov khoom sib txuas . 16-fiber rau 400G SR8 thiab 800G daim ntawv thov.
Tshawb xyuas txoj kev polarity compatibility nyob rau hauv tag nrho cov Cheebtsam. Kev sib xyaw hom A thiab Hom B cables yam tsis nkag siab txog qhov cuam tshuam ua rau tsis muaj - cov channel ua haujlwm.
Qhia meej txog poj niam txiv neej connector kom raug rau koj qhov kev sib txuas ua ke. Document dab tsi yog txiv neej, dab tsi yog poj niam, qhov twg adapter panels mus.
Cov peev nyiaj rau qis- cov khoom poob hauv 100G thiab cov ntawv thov siab dua. Txoj kev poob lej tsis dag.
Npaj rau kev tshuaj xyuas thiab tu. Yuav cov array tshuaj ntsuam xyuas tsim nyog thiab MPO- cov cuab yeej tu tshwj xeeb ua ntej kev teeb tsa pib.
Cov thev naus laus zis ua haujlwm- lab ntawm MPO- mus rau -MPO kev sib txuas ua haujlwm tau ntseeg tau thoob ntiaj teb. Kev vam meej nyob ntawm kev nkag siab txog cov cai thiab ua tiav cov ntsiab lus kom raug. Uas, ncaj ncees, piav txog ntau yam hauv cov ntaub ntawv chaw tsim kho vaj tse.