12 Fiber MTP/MTP OM3 Patch Cable Rau High-Density Fiber Vaj Huam Sib Luag

Xa kev nug
12 Fiber MTP/MTP OM3 Patch Cable Rau High-Density Fiber Vaj Huam Sib Luag
Paub meej
12-Fiber MTP/MTP OM3 High-Density Patch Cable yog positioned raws li fiber ntau interconnection tov rau siab-cov ntaub ntawv ceev ceev thiab telecom backbone networks. Nws yog qhov tsim nyog rau kev tsim kho siab - nrawm thiab siab - fiber ntau suav nrog, suav nrog 10G, 40G thiab 100G daim ntawv thov. Lub hom phiaj cov neeg siv khoom suav nrog cov neeg siv xov tooj, cov chaw khaws ntaub ntawv huab, cov chaw tsim khoom lag luam, cov chaw tsim khoom siv network thiab cov koom ua ke uas xav tau kev sib txuas kho qhov muag txhim khu kev qha thiab siv qhov chaw zoo.
Kev faib tawm yam khoom
MTP MPO Cable Sib Txuas
Share to
Hauj lwm lawm

Txais tos mus yuav 12 fiber ntau mtp / mtp om3 thaj cable rau siab - ntom fiber ntau vaj huam sib luag txuas nrog peb lub Hoobkas. Raws li ib qho ntawm cov ua lag luam thiab cov muag khoom nyob rau hauv Suav teb, peb kuj txais tos cov customized txiav txim. Tham tus nqi thiab cov lus hais nrog peb tam sim no.

 

Ntsiab Technical Specifications

Cov12-Fiber MTP / MTP OM3 Patch Cableyog tsim los nrog 50/125 µm laser- optimized OM3 multimode fiber ntau thiab aqua- lub tsho xim rau kev txheeb xyuas yooj yim hauv siab - ceev cov ntaub ntawv chaw cabling. Lub cable muaj 12 fibers thiab haum rau MTP / MPO-raws li kev sib txuas ntawm caj npab, fiber ntau thaj vaj huam sib luag, cassette modules thiab siab -cov khoom siv kho qhov muag ceev.

 

OM3 fiber ntau tuaj yeem raug teev kom ua tau rawsITU-T G.651.1thiabTIA-492AAACkev xav tau. Nrog ib tug zoo modal bandwidth ntawmNtau tshaj lossis sib npaug rau 2000 MHz · km ntawm 850nm, nws txhawb siab -ceev multimode kis tau tus mob rau luv luv - mus txog cov ntaub ntawv chaw thiab kev lag luam qaum daim ntawv thov.

 

Ob qhov kawg yog txiav nrogMTP / MPO connectors, muaj nyob rau hauv txiv neej los yog poj niam configurations. Txiv neej connectors muaj xws li qhia tus pins, thaum poj niam connectors yog muab tsis muaj pins, cia saj zawg zog txuam nrog transceivers, adapter panels, MTP cassettes thiab ua ntej -tawm cabling systems. Cov kev xaiv polarity suav nrogHom A, Hom B thiab Hom C, txhawb kev sib txawv cabling tsim raws li TIA fiber polarity txoj kev.

 

Rau kev ua haujlwm kho qhov muag, lub cable muaj nyob nrog tus qauv - poob lossis qis - poob MTP / MPO cov kev xaiv xaiv. Hom insertion poob tuaj yeem tswj tau ntawmTsawg dua lossis sib npaug li 0.35 dB, nrog optimized low -poob versions muaj nyob rauTsawg dua lossis sib npaug li 0.25 dB. Qhov siab tshaj qhov poob ntawm ib qhov txuas yog feem ntau teev ntawmTsawg dua lossis sib npaug li 0.75 dB, nyob ntawm cov qib kev ua tau zoo xaiv. Rau multimode PC / UPC polished connectors, rov poob yog feem ntauNtau dua lossis sib npaug li 20 dB.

 

Lub cable yog optimized rau850nm thiab 1310nmkev ua haujlwm. Hauv cov ntawv thov Ethernet, OM3 multimode fiber ntau txhawb nqa10G kis tau tus mob mus txog 300mthiab40G / 100G SR parallel optics txog 100m, raws li hom transceiver, channel insertion poob thiab tag nrho cov peev nyiaj txuas.

Tus qauv siv cable siv lub compact puag ncig cable tsim nrog aramid yarn zog cov tswv cuab rau kev txhim kho tensile kev ua tau zoo thiab kev tiv thaiv txhua yam. Jacket xaiv muaj xws liLSZHrau cov ntaub ntawv hauv tsev ib puag ncig uas tsis muaj pa luam yeeb thiab halogen- yuav tsum muaj kev ua haujlwm pub dawb. LSZH cable tsim feem ntau raug kuaj raws li cov qauv xws li IEC 60332 rau nplaim hluav taws, IEC 60754 rau halogen acid gas emission thiab IEC 61034 rau cov pa luam yeeb ntom.

 

Lub cable tuaj yeem muab tau raws li qhov ntev, kev sib txuas ntawm poj niam txiv neej, hom polarity thiab cov ntaub ntawv tsho kom phim cov txee sib txawv, MTP patching architectures thiab siab - cov kev xav tau ntawm kev xa tawm network.

 

Kev Ntsuas Kev Ua Haujlwm thiab Kev Ua Haujlwm Zoo

Ua ntej xa khoom xa tuaj, txhua lub cable yog raug rau 100% kev ntsuas qhov muag pom, suav nrog kev ntsuas qhov tsis pom, rov qab kuaj qhov poob thiab xaus - tshuaj xyuas ntsej muag. Insertion poob thiab rov qab kev ntsuam xyuas tau ua raws li IEC 61300 series thiab TIA / EIA-568.3 cov qauv kom ntseeg tau tias qhov kev poob qis qis dua los yog sib npaug rau 0.35 dB thiab rov qab poob nyob rau hauv qhov kev teev tseg.

 

Lub ntsej muag lub ntsej muag txuas tau raug tshuaj xyuas siv 3D microscopy cov cuab yeej thiab ua raws li qhov yuav tsum tau ua ntawm IEC 61300-35, kom ntseeg tau tias lub ntsej muag kawg ntawm lub ntsej muag tsis muaj kev khawb thiab kis kab mob. Tag nrho cov khoom raug soj ntsuam nruj me ntsis ua ntej sib dhos. MTP connectors thiab fiber kawg-lub ntsej muag polishing yog ua tiav siv precision automated khoom kom ua tau zoo kho qhov muag kev ua tau zoo thiab siab repeatability.

 

Cov ntaub ntawv kuaj pom pom pom qhov poob hauv qhov ntau ntawm 0.25–0.35 dB thiab UPC rov qab poob ntau dua lossis sib npaug rau 20 dB. Lub connector mating durability yog ntau dua los yog sib npaug rau 500 zaug. Cov khoom lag luam tuaj yeem tsim thiab sim raws li kev ntseeg tau thiab kev ntsuas ib puag ncig xws li IEC 61753-1. Cov txheej txheem tsim khoom yog tswj hwm raws li ISO 9001: 2015 kev tswj hwm kev ua haujlwm zoo kom ntseeg tau tias muaj kev sib luag thiab kev ntseeg tau ntev.

 

Vim li cas thiaj xaiv FOCC 12-Fiber MTP / MTP OM3 Patch Cable?

CovFOCC 12-Fiber MTP / MTP OM3 Patch Cableyog tsim los rau siab -cov ntaub ntawv ceev ceev cabling, telecom backbone txuas thiab modular MTP/MPO fiber ntau architectures. Nws muab cov kev nkag qis qis, kev cog lus ntawm kev sib txuas thiab kev hloov pauv hloov tau yooj yim, ua rau nws muaj txiaj ntsig zoo rau 10G, 40G thiab 100G multimode optical network xa tawm.

 

Rau siab -kev sib txuas ceev, kho qhov muag poob tswj yog ib qho tseem ceeb tshaj plaws. Qhov no MTP OM3 thaj cable yog tsim los nrog precision- polished MTP / MPO connectors thiab nruj fiber ntau alignment tswj. Hom insertion poob tuaj yeem tswj tau ntawmTsawg dua lossis sib npaug li 0.35 dB, thaum optimized qis -v versions tuaj yeem muab rau cov haujlwm uas yuav tsum tau siv nyiaj txuas ntxiv.

 

Rau siab -cov khib nyiab thiab cov txee, lub cable yuav pab txo tus naj npawb ntawm cov kab duplex ib leeg. A 12-fiber MTP/MPO kev sib txuas txhawb nqa kev huv huv, kev tswj xyuas kab yooj yim dua thiab qhov chaw nres nkoj siab dua thaum siv nrog MTP cassettes, adapter panels lossis high-density fiber tis thav ntawv.

 

FOCC kuj txhawb nqa qhov project- raws li kev hloov kho. Cov neeg tuaj yeem xaiv tautxiv neej lossis poj niam MTP / MPO connectors, Hom A, Hom B lossis Hom C polarity, LSZH lossis OFNP cov ntaub ntawv lub tsho, cov kab sib txawv ntawm cov kab uas hla thiab kev cai ntev. Qhov no ua rau lub cable yooj yim rau kev sib koom ua ke rau hauv cov chaw sib txawv cov ntaub ntawv layouts, cov khoom siv hauv xov tooj cua thiab cov phiaj xwm kev sib koom ua ke.

 

Txhua lub cable raug kuaj ua ntej xa khoom xa tuaj rau qhov poob, rov qab poob thiab txuas kawg - ntsej muag zoo. Cov ntaub ntawv xeem tuaj yeem muab tau raws li qhov yuav tsum tau ua, pab cov neeg yuav khoom txo qis kev pheej hmoo ntawm kev teeb tsa thiab txhim kho kev lees paub.

 

Competitive Product Comparison Table

Feature FOCC 12F MTP / MTP OM3 Patch Cable Hom Kev Lag Luam Kev Xaiv A Hom Kev Lag Luam Kev Xaiv B
Hom Fiber OM 3 50/125µm multimode fiber ntau OM 3 50/125µm OM 3 50/125µm
Hom Connector MTP/MPO txiv neej lossis poj niam xaiv tau MTP/MPO txiv neej los yog poj niam Feem ntau poj niam-rau- poj niam
Hom Insertion Poob Tsawg dua los yog sib npaug rau 0.35 dB, qis - kev xaiv poob muaj Nyob ib ncig ntawm 0.35 dB nyob ntawm qib Tsawg- qib poob, feem ntau nyob ib puag ncig<0.35 dB
Rov Los Los Ntau dua lossis sib npaug rau 20 dB UPC raug Ntau dua lossis sib npaug rau 20 dB UPC raug Ntau dua lossis sib npaug li 20 dB lossis siab dua nyob ntawm qib connector
Kev xaiv polarity Hom A / Hom B / Hom C Feem ntau Hom A / Hom B Feem ntau Hom A / Hom B
Jacket Options LSZH / OFNP yeem LSZH lossis OFNP nyob ntawm SKU OFNP sib
Cable Diameter 2.0mm / 3.0mm yeem, qhov project-raws li Feem ntau 2.0mm lossis 3.0mm Feem ntau 3.0mm
Daim ntawv thov Cov chaw zov me nyuam, xov tooj cua qaum, siab -Density IDC, MTP cassette systems Cov chaw khaws ntaub ntawv thiab siab - cabling Data centers, enterprise networks thiab plenum installations
Muab Khoom Zoo Factory-kev hloov kho ncaj qha, batch ntau lawm, hloov tau yooj yim Standardized online SKU qauv Khw muag khoom -style txheem configuration

 

Ntim, Qauv Number thiab Ordering Options

FOCC muab cov khoom siv12-Fiber MTP / MTP OM3 Patch Cablenrog kev tiv thaiv ntim tsim rau kev thauj mus los ntawm fiber ntau optic cable. Txhua lub xov tooj yog coiled nrog khoov kom raug- radius tswj thiab ntim rau hauv lub hnab ntim khoom lossis lub thawv tiv thaiv kom txo tau cov neeg kho tshuab kev ntxhov siab thaum khaws cia thiab xa khoom. Cov ntaub ntawv soj ntsuam kho qhov muag, cov ntawv cim khoom thiab cov ntaub ntawv thev naus laus zis tuaj yeem suav nrog raws li qhov yuav tsum tau ua.

Ua kom kev txiav txim yooj yim dua, cov qauv khoom tuaj yeem txhais tau los ntawm kev suav fiber ntau, hom kev sib txuas, qib fiber ntau, polarity, cov khoom siv lub tsho thiab cov kab ntev. Ib tug qauv code yog:

12F-MTP-MTP-OM3-A-LSZH-5M

 

Cov qauv no sawv cev rau a12-fiber MTP / MTP OM3 multimode thaj cablenrogHom A polarity, LSZH tshothiab5-meter cable ntev.

 

FOCC txhawb nqa tus qauv ntev xws li1m, 2m, 3m, 5m thiab 10m, nrog rau qhov ntev customized rau cov rack layouts, MTP cassette systems, optical tis thav duab thiab cov ntaub ntawv hauv nruab nrab qaum kev sib txuas. Muaj cov kev xaiv muaj xws litxiv neej lossis poj niam MTP / MPO connectors, Hom A / Hom B / Hom C polarity, LSZH lossis OFNP cov ntaub ntawv tshothiab sib txawv cable diameters raws li kev teeb tsa ib puag ncig.

 

Ua ntej kev tsim khoom loj, FOCC lees paub tag nrho cov kev teeb tsa cable nrog cov neeg siv khoom, suav nrog kev sib txuas ntawm poj niam txiv neej, polarity, fiber ntau, cov khoom siv lub tsho, cable ntev, daim ntawv lo thiab ntim khoom. Qhov no yuav pab txo qis kev txiav txim yuam kev thiab xyuas kom MTP / MPO cable yog npaj rau kev teeb tsa thaum xa khoom.

 

Ua raws, Warranty thiab Project Support

Cov12-Fiber MTP / MTP OM3 Patch Cabletuaj yeem muab nrog RoHS thiab REACH cov ntaub ntawv ua raws cai rau cov neeg siv khoom xav tau cov ntaub ntawv kev nyab xeeb thiab cov ntaub ntawv ib puag ncig. Kev tsim khoom thiab kev tshuaj xyuas yog tswj hwm raws li ISO 9001: 2015 kev tswj hwm kev ua haujlwm zoo los txhawb nqa cov khoom zoo ib yam.

 

Rau kev ua haujlwm kho qhov muag thiab kho qhov muag, cov khoom tuaj yeem raug kuaj raws li cov txheej txheem IEC thiab TIA. Connector kawg-kev tshuaj xyuas lub ntsej muag, kev kuaj tsis pom thiab rov qab kuaj qhov poob tuaj yeem raug sau ua ntej xa khoom. Qhov project- cov ntawv ceeb toom tshwj xeeb muaj rau kev teeb tsa cov ntaub ntawv chaw, kev txais xov tooj thiab cov phiaj xwm kev sib koom ua ke.

 

FOCC muab tus qauv ib - xyoo lav rau cov khoom no. Rau kev txiav txim ntau, OEM tej yaam num lossis ntev - daim ntawv cog lus muab khoom, txhim khu kev ruaj ntseg cov ntsiab lus thiab cov ntaub ntawv soj ntsuam customized tuaj yeem sib tham raws li qhov yuav tsum tau ua.

Cim npe nrov: 12 fiber ntau mtp / mtp om3 thaj cable rau siab - ntom fiber ntau vaj huam sib luag kev twb kev txuas, Tuam Tshoj, Hoobkas, lwm tus neeg, manufacturers, quotation, customized, nqe, yuav

Xa kev nug